PUMP
Installation Tips to Ensure Proper Performance
A. With High Flow Rate (greater than 80 gpm) Install
T-fi ttings exactly as shown.
C. Pool and Spill-over Spa Combination
B. With In-Floor Cleaner - TWO OPTIONS
PUMP
PUMP
POOL WATER LEVEL
POOL WATER LEVEL
Flow
Flow
HEATER
The best option is to have two lines.
One line with pump, fi lter, heater and
New Water Cycler and a second line with a separate pump for the in-fl oor
cleaning system (fi lter optional).
OPTION 1- A Two-Line Installation
OPTION 2 - A 3-Way Valve Installation
POOL WATER LEVEL
POOL WATER LEVEL
POOL WATER LEVEL
POOL RETURN
3-way manual valve or 3-way motor valve plus controls
NEW WATER
CYCLER
NEW WATER
CYCLER
IN-FLOOR
CLEANER VALVE
IN-FLOOR
CLEANER VALVE
Line 1
Line 2
TO POOL
NEW WATER CYCLER
CHECK
VALVE
SUCTION
FROM
POOL/SPA
T
O
POOL
T
O
SP
A
3-WAY VALVE
NEW WATER
CYCLER
CHECK VALVE
PUMP
SUCTION
FROM
POOL/SPA
IMPORTANT:
Over chlorination or damage to the New
Water Cycler or other equipment could result if special
installations A, B or C are not used in these situations:
1) If using a multi-speed pump, run
pump for at least 6 hours per day at
high speed (at least 40 gpm).
If the pump will run on low speed 24
hours per day or less than 6 hours per
day on high speed, you must bleed the
air while the pump is on by unscrewing
either the cap knob or back knob until
water appears. Then screw the knob
back in. Repeat this process each time
the cap is removed for any reason.
2) Install Cycler with 4-8 psi back pressure.
Lower back pressures could result in under
chlorination. Change the eyeball fi ttings in
the return jets to a smaller size to increase
back pressure. Contact King Technology at
800-222-0169 for a specially designed
Cycler pressure gauge to determine back
pressure at pool start-up.
3) Special installation Requirements:
•
If water fl ow is higher than 80 gallons per minute (gpm),
see diagram A.
•
If an in-fl oor cleaner is included with pool,
see
diagram B, with two options. Preferred
installation is Option 1 with two separate lines.
•
If set-up is a pool and spa combination with
common equipment, see diagram C.
Questions?
Call Customer Service at 800-222-0169
Monday thru Friday, 8 am to 5 pm central standard time.
WARNING
• Do not exceed maximum operating pressure of 50 psi.
• Do not install automatic or fast shut off valves
downstream of feeder.
• Always install the New Water Cycler AFTER the
heater (if applicable) on the return line.
• Always install any additional sanitizing equipment
AFTER and NEVER BEFORE the New Water Cycler
is installed on the return line.
PN #01-22-4000