COMPRESSOR CONTROLS

ADDITIONAL REGULATORS AND CONTROLS 

 
Since the air tank pressure is usually greater than that which is needed, an 
air pressure regulator should be employed to control the air pressure ahead 
of any individual driven device. An air control unit which combines the       
function of air regulation, moisture and dirt removal should be used.  
 

OPERATION CONTROLS 

 

CHECK VALVE (A) FIG.7 (FITTING NOT VISIBLE). 

When the air                

compressor is operating, the check valve is “open”, allowing compressed air 
to enter the air tank. When the air compressor reaches its “Cut-Out” pressure, 
the check valve “closes”, allowing air pressure to remain inside the air tank. 
 

TANK PRESSURE GAUGE (A) FIG. 8. 

The tank pressure gauge indicates 

the reserve air pressure in the tank. 
 

ON/AUTO-OFF SWITCH (B) FIG.8. 

Turn this switch ON to provide power to 

the automatic pressure switch and OFF to remove power at the end of each 
use. 
 

PRESSURE SWITCH (C) FIG.8. 

The pressure switch automatically starts the 

motor when the tank pressure drops below the factory set “Cut-In” pressure. 
It also stops the motor when the air tank pressure reaches the factory set 
“Cut-Out” pressure. 

 
ASME SAFETY VALVE (D) FIG. 8.

 If the pressure switch does not shut off 

the air compressor at its cutout pressure setting, the safety valve will protect 
against high pressure by “popping out” at its factory set pressure (slightly 
higher than the pressure switch cut-out setting). 
 

WARNING!

: If the safety valve does not work properly, over pressurization 

may occur, causing air tank rupture or an explosion. Daily pull the ring on the 
safety valve to make sure that the safety valve operates freely. If the valve is 
stuck or does not operate smoothly, it must be replaced with the same ASME 
type of valve. 

 
BALL VALVE OUTLET PRESSURE LEVER (E) FIG. 8.

 This lever controls 

the amount of pressurized air in the air delivery piping system.  
 

DRAIN VALVE (A) FIG.9.

 The drain valve is located at the base of the air 

tank and is used to drain condensation at the end of each use. Turn drain 
valve counterclockwise to open (no pressure build-up) or clockwise to close 
it (permits pressure build-up). 
 

MOTOR THERMAL OVERLOAD PROTECTOR (RESET (A) FIG.10). 

The 

electric motor has an automatic thermal overload protector. If the motor    
overheats for any reason, the thermal overload protector will shut off the 
motor. The motor must be allowed to cool before restarting. Wait for motor to 
cool down, once motor is cool, press the reset button and restart.

FIGURE 7

FIGURE 8

FIGURE 9

FIGURE 10

Summary of Contents for KC-6160V3

Page 1: ...INSTRUCTION MANUAL MODEL KC 6160V3 COPYRIGHT 2020 ALL RIGHTS RESERVED BY KING CANADA TOOLS INC STATIONARY 6 5 PEAK HP 60 GALLON AIR COMPRESSOR ...

Page 2: ...e abuse normal wear and tear negligence or accidents repairs done by an unauthorized service center alterations and lack of maintenance King Canada shall in no event be liable for death injuries to persons or property or for incidental special or consequential damages arising from the use of our products To take advantage of this limited warranty return the product at your expense together with yo...

Page 3: ... exposed metal such as the compressor head or outlet tubes can result in serious burns HOW TO PREVENT IT Never touch any exposed metal parts on compressor during or immediately after operation The compressor will remain hot several minutes after use Do not reach around protective shrouds or attempt maintenance until the compressor has cooled down completely RISK OF PROPERTY DAMAGE WHEN TRANSPORTIN...

Page 4: ...he grounding screw on the pressure switch See grounding information below Warning Do not attempt to hard wire this compressor yourself unless you are a qualified electrician Overheating short circuiting and fire damage will result from inadequate wiring Electrical wiring codes local or provincial may differ from area to area Source wiring plug and protector must be rated for at least the amperage ...

Page 5: ...re the compressor is properly wired to electrical source and grounded if a power cord was installed plug the power cord into a grounded 240V branch circuit receptacle 3 Make sure the oil level in the crankcase reaches the centre dot of the oil sight glass A Fig 4 refer to maintenance section for instructions on fill the crankcase with oil 4 Open the drain valve A Fig 5 turn it counterclockwise thi...

Page 6: ...AFETY VALVE D FIG 8 If the pressure switch does not shut off the air compressor at its cutout pressure setting the safety valve will protect against high pressure by popping out at its factory set pressure slightly higher than the pressure switch cut out setting WARNING If the safety valve does not work properly over pressurization may occur causing air tank rupture or an explosion Daily pull the ...

Page 7: ...level Oil level must be in the centre of the red dot of oil sight glass 2 Drain condensation from tank 3 Check for any unusual noise or vibration 4 Be sure all nuts and bolts are tight Monthly 1 Inspect air system for leaks by applying soapy water to all joints Tighten those joints if leakage is observed Initial oil change must be done after the first 100 hours 1 Once initial oil change is done af...

Page 8: ... Crankcase breather valve malfunction Worn piston rings Piston rings not seated CORRECTIVE ACTION Check voltage or eliminate extension cord or reset Check wiring connections Wait for motor to cool then press the reset button restart Drain tank of air pressure Check valve manually by pulling If condition persists replace Close drain cock Clean or replace as necessary Replace check valve Check for p...

Reviews: