Shenzhen Kingbird network technology CO.,LTD
KB2000 Data Converter(for Internet)
4
3
.
The parameters of KB2000
3.1 General parameters
Name: Named current KB2000, the Max length is 16bytes (ASCII code);
Password: When you set the parameters of KB2000, you must input password,
password is 6bytes ASCII code;
Type: Include A and B two types. Type A is mainly used in Main station, Type B is
mainly used in slave station;
ID: Current KB2000’s ID;
Target ID: If the type of KB2000 is type A, this item just is used. When type A
wants to communicate with type B, this item value is set to the ID of type B;
Zone valid: If you want to use Zone, you must set it to ON;
Zone: The current KB2000’s Zone number of the Network; if type A wants to
communicate with a quantity of type B, you must set type A and type B the same Zone
number, and the Zone valid all be set ON;
Heart beat: The interval of KB2000 connection or communicate with remote
server.
3.2 Network parameters
IP: IP address of KB2000, when it join into one subnet, its IP must be distributed
depend on the network section.
Gateway: The gateway of subnet which KB2000 accessed.
Subnet Mask: It depends on the subnet.
Get IP from: The type of getting IP include Manually and Automatic. In Manually,
IP address can be set, KB2000 will use the IP address which user set.
If in Automatic,
KB2000 can get the IP address by DHCP protocol, DHCP server must be in the
subnet, if you can not get IP through automatic, please use manually.
Protocol: Network protocol support UDP and TCP;
Target IP: KB2000 is client-side working way, it must have server IP.The default
value is Kingbird’s, if user don’t have server, can use Kingbird’s server for free (if
quantity is less) or hire Kingbird’s server (if quantity is more), then this value no need
to reset.
Target TCP port: The TCP port for specified KB2000 communicate with Target
Main machine, The default value is the TCP port of Kingbird’s, if user don’t have
server, can use Kingbird’s server for free (if quantity is less) or hire Kingbird’s server (if
quantity is more), then this value no need to reset.
Target UDP port: The UDP port for specified KB2000 communicate with Target
Main machine, The default value is the TCP port of Kingbird’s, if user don’t have
server, can use Kingbird’s server for free (if quantity is less) or hire Kingbird’s server (if
quantity is more), then this value no need to reset.