 Shenzhen Kingbird network technology CO.,LTD

       

KB2000 Data Converter(for Internet)

 

                           

 

 

                         

 

    5

3.3 COM parameters

 

Baud rate: The data transmit speed. User must set it same as PC or terminal 

device which connected. The bard rate of KB2000 support from 300pbs to 115200pbs; 

 Data bits: In COM port asynchronous transmission, a group data real include data 

digit. KB2000 support 5-8Bits data bits. Data bits must be set the same as the PC or 
terminal device which connected. In general it is 8bits; 

 Verify: KB2000’s COM verify have three types: None, Even, Odd. User must set it 

same as PC or terminal device which connected. 

 Stop bits: In COM port asynchronous transmission, a data digit to indicate the end 

of this group data

KB2000 support one and two stop bits. User must set it same as 

PC or terminal device which connected. In general the stop bits is 1bit;

 

 Max MEM. Time: When KB2000 received data from COM port, it will go into the 

buffer, if over Max MEM Time, and there are not next data come in, KB2000 will 
transmit the data to the network. 

 Max MEM. Bytes: When KB2000 received enough length data from COM port, 

KB2000 will transmit the data to the network. KB2000 will transmit the data to network 
when it satisfies Max MEM. Time and Max MEM. Bytes in one of two conditions. 

4

Operation and Management 

 Firstly user is advised to connect KB2000 with the same subnet through network 

cable by Switch or HUB, and power on it, User can set KB2000. 

User can Manage KB2000 with the program (NetConvertor.exe). NetConvertor 

can manage all KB2000 in current subnet. It can search KB2000, view KB2000 
parameters, set KB2000 and so on. The interface of the program as follow: 

Summary of Contents for KB2000

Page 1: ... Manual Shenzhen Kingbird Network Technology CO LTD Add 12C 12D Tower B Haiwang Building NanHai Road Nanshan District Shenzhen Guangdong China TEL 86 755 82556825 83239613 Fax 86 755 83239613 EXT 8012 Web http www kingbirdnet com EMAIL sales kingbirdnet com MSN kingbird_sales1 hotmail com SKYPE kingbird_sales1 ...

Page 2: ...etwork environment KB2000 can apply to all kinds of network environment network parameter and COM parameter KB2000 can be set by configuration software or by User s programming Two types of KB2000 Type A KB2000 A this type mainly for Main station Master station as control center it commonly connect with PC Type B KB2000 B this type mainly for slave station as remote terminal it commonly connect wi...

Page 3: ... Description For User 1 VCC Power DC6 24V 2 GND Ground 3 UTXD TXD DTU COM RS485 A RS232 TTL RXD RS485 A 4 URXD RXD DTU COM RS485 B RS232 TTL TXD RS485 B 5 Output1 Output NO 1 of IO 6 Input1 Input No 1 of IO 7 UGND Ground COM RS232 TTL RS485 Data groud 8 Output2 Output No 1 of IO 9 Status Online is high offline is low 10 Input2 Input No 2 of IO VCC GND UTXD1 A URXD1 B Output1 Input1 GND Output2 sta...

Page 4: ...f subnet which KB2000 accessed Subnet Mask It depends on the subnet Get IP from The type of getting IP include Manually and Automatic In Manually IP address can be set KB2000 will use the IP address which user set If in Automatic KB2000 can get the IP address by DHCP protocol DHCP server must be in the subnet if you can not get IP through automatic please use manually Protocol Network protocol sup...

Page 5: ... one and two stop bits User must set it same as PC or terminal device which connected In general the stop bits is 1bit Max MEM Time When KB2000 received data from COM port it will go into the buffer if over Max MEM Time and there are not next data come in KB2000 will transmit the data to the network Max MEM Bytes When KB2000 received enough length data from COM port KB2000 will transmit the data t...

Page 6: ...er can find all KB2000 through Search in the subnet Please chose File menu then Search Or you can click Search button on the toolbar 4 2 View parameters Please double click the icon of KB2000 that searched or after you searched KB2000 you can click Parameters button on the toolbar Just as below picture ...

Page 7: ...button in this dialog read the parameters again 4 3 Set KB2000 If you want to amend parameters of KB2000 you can set them in the parameters setting dialog Chose a KB2000 in the list then click parameters button in the toolbar you will go to the parameters setting dialog the interface as follow ...

Page 8: ...d can not be required 3 Some parameters must not be changed the software have forbid them 4 If you want to use IO function please ask for IO control protocol from our company 5 Setup Network and Application 5 1 KB2000 Application Step 1 Set KB2000 Network Parameters Generically KB2000 is connected with internet through LAN First net parameters need to be set according to the situation of LAN Pleas...

Page 9: ... After set the KB2000 A and KB2000 B and connect with network you can run SCADA software to read or control or AMR Note The communication way of SCADA software must base on COM RS232 RS485 In the SCADA software please open the COM port that be connected with KB2000 A its baud rate and data format must be same with KB2000 A 6 plug and play Solution 6 1 KB2000 A Work with KB2000 B KB2000 is used as ...

Page 10: ... remote equipments or devices KB2000 A will send TCP connection request to specified server and communicate after power on At the same time KB2000 B which connect with equipments or devices send TCP connect request to server after they are connected the PC and the remote equipments or devices can be communicate each other In other words the PC can communicate with every KB3000 The quantity of KB30...

Page 11: ...In this way when a host needs to communicate with device Appserver software send TCP connection request to designated server then communication with it At the same time the KB2000 B which connected with device sends the TCP connection request to server after connection established KB2000 B can communicate with server then user can use Appserver software in host communicate with every KB2000 B thro...

Page 12: ...Shenzhen Kingbird network technology CO LTD KB2000 Data Converter for Internet 12 The Appserver interface as follow The system schematic structure as follow ...

Page 13: ...ve been used other KB2000 network device or PC 7 2 When the KB2000 connect with Switch or HUB please use direct cable when the KB2000 connect with PC please use Cross cable TCP IP TCP IP TCP IP Internet PC User monitoring software Appserver software KB2000 B Internet Server KB2000 B KB2000 B Device 1 Device 2 Device N RS232 RS485 RS232 RS485 RS232 RS485 TCP IP ...

Page 14: ...es for repair replacement or compensation of faulty products But if it because force majeure user open or modify it himself without permission our company can not supply three guarantees User can replace products if he bought product within one month which installation and use regularly Guarantee repair free of charge period one year Maintain for life Packing list Item NO Name quantity unit memo 1...

Reviews: