Shenzhen Kingbird network technology CO.,LTD
KB2000 Data Converter(for Internet)
9
(1)You’d better set get IP from: By manually, for your LAN may have no DHCP
server.
(2) Generically KB2000-A and KB2000-B are not in one LAN, so you must set
different network parameters depend on the LAN which be connected.
2
.
Set other parameters
KB2000’s other parameters as baud rate, data format and so on, You can set
them depend on your device.
Other parameters as ID, Target ID, heard beat, No need to reset.
3
.
Connect with KB2000
KB2000-A connect with PC: Connect its RJ45 interface with the switch or
Router of the LAN by network cable, then connect the RS232 interface with the
COM of PC by RS232 cable.
KB2000-B connect with the device: Connect its RJ45 interface with the switch
or Router of the LAN by network cable, then connect its COM port with RS232 or
RS485 of the device.
4
.
Run SCADA software to read/control
After set the KB2000-A and KB2000-B and connect with network, you can run
SCADA software to read or control (or AMR)
Note: The communication way of SCADA software must base on COM
(RS232/RS485).
In the SCADA software, please open the COM port that be
connected with KB2000-A, its baud rate and data format must be same with
KB2000-A.
6 . “plug and play” Solution
6.1 KB2000-A Work with KB2000-B
KB2000 is used as Client-side, it is applied to single PC or multi-PC system. The
single PC or multi-PC can communicate with remote equipments or devices. In this
way, KB2000-A is used as Client-side. When the host machine needs to communicate
with remote equipments or devices, KB2000-A will send TCP connection request to
specified server and communicate after power on.
At the same time KB2000-B which
connect with equipments or devices send TCP connection request to server, after they
are connected, the PC and remote equipments or devices can be communicated each
other. In other words the PC can communicate with every KB2000-B. The quantity of
KB2000-B can be unlimited.