MAINTENANCE
CAUTION: Before starting any maintenance or cleaning jobs, the compressor
has to be switched off and disconnected from the power supply!
Make sure the compressor accessories and air tools are relieved from pressure.
Be sure that all safety and protection devices are operational after having
finishing maintenance or cleaning jobs.
Take care to remove all service tools from the compressor before starting to work
again.
Other maintenance jobs than described in this manual have to be done by an
authorized service center.
After approx. 30 hours operating time:
Drain pressure tank. Turn drain valve at the bottom of the tank counterclockwise,
until compressed air will escape. Any condensed water will be exhausted at the
same time.
Inspect air filter and air vents. Remove any material that my have gotten stuck in
the are vents.
Clean the exterior of the compressor. Wipe off any dirt or dust that has
accumulated on the air tank and housing.
Every month
Check the safety valve for leaks or dirt. If necessary clean or replace.
Every 2 months
Clean air filter. First take off the motor housing from the air compressor. This is
done by unscrewing the 2 hex bolts on the top of the housing. Then screw the air
filter off the compressor using a wrench # ½ “. (see FIG. 7 and FIG. 8) Rinse the
air filter in AIR TOOL OIL, than blow out any dust that may still remain and dry
thoroughly. Replace filter in reverse order.
FIG. 7
FIG. 8