Technical date sheet:
What is included:
12 Pieces of Individual Receiver Modules .
1 Piece of 3x20channel Transmitter-KFE2201C/60
1 Instruction Manual.
What is not included:
Batteries for Modules and Transmitter.
Deprogramming module and re-programming
You must deprogram the system prior to trying to re-program the module. This
system has a fail-safe for digital rectifying that will prevent accidental code storage
thereby creating a secure firing environment..
Step 1. Press and hold the
P
(program) button. The red LED above the button will
illuminate for about 10 seconds. This LED light will go out when the code is deleted.
Step 2. Ensure that the transmitter(KFE2201C/60) is on and the slide switch is in 1-3
position. Extend the antenna on the receiver module. Press and release the
P
(program) button again. Immediately, press any button of the transmitter. Keep your
fingers on the button until you see the signal LED blink. Which indicates the receiver
module has locked onto the signal.
Step 3. You can test the receiver module by pressing the corresponding firing button
on transmitter.
Firing mode definitions:
Single Fire: Fire individual cue.
All Fire: Will fire all cues from all the receiver modules on the selected firing button
on transmitter at once.
CONT (Sequence Fire): Will fire all cues in sequence from one receiver module to
another with a pre-set time delay between cues. There is the time marks below the
firing buttons of transmitter.
Step Fire: Every time you push the step firing button on transmitter a cue will fire
from one receiver module to another.
How to program:
1.
Single fire:
Set the communication between receiver and any firing button from 1-20. The
corresponding firing button can control the receiver module.
2.
Sequence fire:
Example receiver modules A, B, C.
Step 1. Set the communication between receiver A and firing button 1.
Set the communication between receiver B and firing button 2.
Set the communication between receiver C and firing button 3.
Step 2. Select the time delay button (Example button 17. the time delay is 2
second). Keep pressing this button, then press and release the
P
buttons on
receiver modules A,B,C. You will see the signal LED will blink twice.
Step 3. Press CONT firing button, then every cue of receiver modules will fire at a
time delay of 2.0 seconds.
3.
Step fire:
Example receiver modules A, B, C.
Step 1. Do the same as Step 1 (in sequence fire mode above)
Step 2. Keep Pressing
STEP
firing button, then press and release the
P
buttons on
receiver modules A,B,C. You will see the signal LED will blink twice.
Step 3. Every time press
STEP
firing button, a cue will fire from receiver A to B to C.
4.
All fire:
Example receiver modules A, B, C.
There is two way to program it.
1, Do the same steps as Step 1(in sequence fire mode above)
Keep pressing
ALL
firing button, then press and release the
P
buttons on receiver
modules A,B, C. You will see the signal LED will blink twice. Then press the
ALL
button. All the cues from A, B, C receivers will fire together.
2. Select one firing button from 1-20. For example, we choose button 1. Set the
communication between each receiver module and firing button 1. then press
button 1, all the cues from A, B, C receiver modules will fire together.
Module Size (cm)
5.5 x 5 x 4
Inner power (V)
4 x 1.5v AAA batteries
Unit weight (kg)
0.05
Test current (MA)
0.9
Range (meter)
150
Output power(V)
6.0
Page 3 of 6