Warning!
The stove is still hot in the following time after the fire has been
extinguished.
Recommended Fuels
Fuels vary greatly in quality and performance. Anthracite is an approved natural
smokeless fuel( not processed). Sufficient air supply and above average fuelbed
temperatures are required to maintain best performance for this fuel, therefore, we
suggest the fuel is used in combination with other approved manufactured
smokeless fuels as per the HETAS approved list.
The following fuels are approved in closed appliance by HETAS Ltd.: Coalite
Cosycoke
Coalite Nuts Pureheat
Blazebrite Supercoke
Homefire Maxibrite
Homefire Ovals Newflame
Phurnacite Supacite
Mixed Nuts Fireglo Ovoids
Ancit Dragonbrite
Taybrite Anthracite Small Nuts
Sunbrite Doubles Wood Logs
You should only use authorized smokeless fuels in smoke control areas .
Warning!
The use of the appliance as an incinerator and the uses of liquid,
unsuitable and non recommended fuels are prohibited.
If any difficulties and problems on fuel, consult your local approved fuel merchant.
HETAS Ltd.- Telephone 01242 673257- www.hetas.co.uk
Solid Fuel Association-Telephone 0800 600 000- www.solidfuel.co.uk
Safety guidance
FIRES CAN BE DANGEROUS
-Do use a fireguard in the presence of children,
the elderly or the infirm. The fireguard should be consistent with
BS6539-Fireguards for use with solid fuel appliances.
DO NOT OVERFIRE
- overfire can be dangerous. If any part of the stove grow
red, it shows overfire do occur. It means the use beyond its design capacity is not
allowed, and you should keep an eye on how it is burning and adjust the control
accordingly;
FUME EMISSION
Emit fumes can be avoided if it is installed and operated properly, fumes usually
appear from operations of de-ashing and refueling. Constant fume must be boring.
If fume emission does persist, then the following measures can be helpful:
TM