background image

Warning!

  The  stove  is  still  hot  in  the  following  time  after  the  fire  has  been 

extinguished. 

Recommended Fuels 

Fuels  vary  greatly  in  quality  and  performance.  Anthracite  is  an  approved  natural 
smokeless  fuel(  not  processed).  Sufficient  air  supply  and  above  average  fuelbed 
temperatures are required to maintain best performance for this fuel, therefore, we 
suggest  the  fuel  is  used  in  combination  with  other  approved  manufactured 
smokeless fuels as per the HETAS approved list. 
The  following  fuels  are  approved  in  closed  appliance  by  HETAS  Ltd.:    Coalite                                                     
Cosycoke 
Coalite Nuts                                            Pureheat 
Blazebrite                                                Supercoke 
Homefire                                                    Maxibrite 
Homefire Ovals                                        Newflame 
Phurnacite                                                Supacite 
Mixed Nuts                                                Fireglo Ovoids 
Ancit                                                          Dragonbrite 
Taybrite                                                    Anthracite Small Nuts 
Sunbrite Doubles                                    Wood Logs 
You should only use authorized smokeless fuels in smoke control areas . 

Warning! 

The  use  of  the  appliance  as  an  incinerator  and  the  uses  of  liquid, 

unsuitable and non recommended fuels are prohibited. 
If any difficulties and problems on fuel, consult your local approved fuel merchant. 
 

   

 
HETAS Ltd.- Telephone 01242 673257- www.hetas.co.uk 
Solid Fuel Association-Telephone 0800 600 000- www.solidfuel.co.uk 

Safety guidance 

FIRES  CAN  BE  DANGEROUS

-Do  use  a  fireguard  in  the  presence  of  children, 

the  elderly  or  the  infirm.  The  fireguard  should  be  consistent  with 
BS6539-Fireguards for use with solid fuel appliances. 

DO  NOT  OVERFIRE

-  overfire  can  be  dangerous.  If  any  part  of  the  stove  grow 

red, it shows overfire do occur. It means the use beyond its design capacity is not 
allowed,  and  you  should  keep  an  eye  on  how  it  is  burning  and  adjust  the  control 
accordingly; 

FUME EMISSION 

Emit  fumes  can  be  avoided  if  it  is  installed  and  operated  properly,  fumes  usually 
appear from operations of de-ashing and refueling. Constant fume must be boring.   
If fume emission does persist, then the following measures can be helpful: 

TM 

STOVES 

Summary of Contents for BSV-01SERIES

Page 1: ...BSV 703 BSV 704 BSV 801 BSV 8 02 BSV 803 BSV 804 BSV 805 PLEASE READ THIS USER S INSTRUCTIONS CAREFULLY WHEN YOU ASSEMBLE INSTALL OPERATE AND MAINTAIN YOUR STOVES IF ANY MORE QUESTIONS PLEASE CONTACT OUR DEALERS IN YOUR LOCAL PLACE DEALER STAMP EN13240 2001 Manufacturer Xuzhou Best Art Crafts Co Ltd Second floor South building No 390 Fuxing South Road Xuzhou City Jiangsu 221000 P R China ...

Page 2: ...W Same above 175kg 715 460 720 mm BSV03 grey iron 18 12 kW Same above 130kg 665 455 665 mm BSV04 grey iron 18 16kW Same above 200kg 710 535 820 mm BSV05 grey iron 18 8 kW Same above 90kg 560 440 460 mm BSV06 grey iron 18 8kW Same above 93kg 560 440 460 mm BSV07 grey iron 18 6kW Same above 76kg 590 360 470 mm BSV08 grey iron 18 7kW Same above 83kg 610 410 470 mm BSV09 grey iron 18 8 kW Same above 9...

Page 3: ...SV804 grey iron 18 14kW Same above 170kg 730 470 730 mm BSV805 grey iron 18 12Kw Same above 130kg 680 420 580 mm BSV21 grey iron 18 5kW Same above 68 kg 630 340 440 mm BSV22 grey iron 18 7 kW Same above 80 kg 650 380 460 mm BSV23 grey iron 18 7 kW Same above 80 kg 670 380 460 mm BSV24 grey iron 18 7 kW Same above 80 kg 670 390 480 mm BSV25 grey iron 18 6 kW Same above 75 kg 680 350 480 mm BSV26 gr...

Page 4: ...ith the set of bolts and washers do not over tighten Legs are supplied packed inside the stove Remove the crate and take out all the components Remove the protective plywood panel on the bottom of the stove TM STOVES ...

Page 5: ...ons including those referring to national and European Standards need to be complied with when installing the appliance We are not responsible for any fault arising through incorrect installation Always have the stove installed by a competent person and ensure its installed with accordance to your local building regulations UK customers should consider using a HETAS installer Visit www hetas co uk...

Page 6: ...fitted in accordance with manufacturer s instructions and Building Regulations The chimney height and the position of the chimney terminal should conform to Building Regulations and all local regulations including those referring to national and European Standards The chimney must be in good condition and any cracks and obstructions are not permitted The diameter of the flue should not be less tha...

Page 7: ...perienced in solid fuel heating installations These must be provided an expansion tank open to the atmosphere an indirect cylinder a gravity circulation to one radiator to dissipate heat when the pump is off the fitting of a low limit thermostat to the primary return to ensure the pump dose not operate when return water temperatures are less than 50 C a drainage tap in the return flow Air Supply A...

Page 8: ...important to know how to use the stove properly and use only the recommended fuels for this appliance The user should know how to have smoke or fumes emitted properly from the stove and be warned to prevent injuries in case of the presence of children aged or infirm persons Operating Instructions WARNINGS AND IMPORTANT All local regulations including those referring to national and European Standa...

Page 9: ...rd and backward to de ash For grid style grate a special hook is supplied to de ash It is highly recommended to de ash regularly in case any build up of ash will damage the cast iron fuelbed You should be careful of hot parts of the appliance in operation Ashpan You should clean up the ashpan regularly Use the supplied appropriative tool to pull the ashpan out of the stove on solid mineral fuels P...

Page 10: ...een cut split and stacked for at least one year in circulating air surround to dry out Otherwise wet or unseasoned wood will cause tar deposits in the stove and unsatisfactory heat output will occur Ignition It is better for you to have 2 or 3 small fires before operating your stove to its maximum heat output This can help the paint to cure steadily and to give a long service life of the paint fin...

Page 11: ...Warning The use of the appliance as an incinerator and the uses of liquid unsuitable and non recommended fuels are prohibited If any difficulties and problems on fuel consult your local approved fuel merchant HETAS Ltd Telephone 01242 673257 www hetas co uk Solid Fuel Association Telephone 0800 600 000 www solidfuel co uk Safety guidance FIRES CAN BE DANGEROUS Do use a fireguard in the presence of...

Page 12: ... in order to check the area for signs of spread MAINTENANCE Stove body Use a soft brush to clean the stove cleaning must be given after it has cooled down The finish can be renewed with proprietary stove paint Baffle plate Remove and clean the baffle plate once a month to avoid soot or fly ash blocking the flue ways and producing dangerous fume emission Fireproof glass use a proprietary glass clea...

Page 13: ...lers in your local place Trouble clearing No Fire can be burnt Please check the following measures A proper fuel is being used The air inlet is unobstructed Chimneys and flueways are clear Sufficient air supply is into the room No extractor fan is working in the same room as the stove Fire blazing out of control Please Check A suitable fuel is being used The doors are tightly closed The air contro...