Page 16 of 23
Kingkraft can supply 6 month ‘Care Packs’ whirlpool cleaner, which may be used to clean the whirlpool
system. Instructions are given on the package. Other whirlpool cleaning liquids and tablets can be
used.
Kingkraft also recommend Chemgene® / Trigene®, which is available from Kingkraft.
Alternative special preparations may be available from either your bathroom centre or plumbers’
merchant - be sure to follow the manufacturers instructions carefully.
Please note these instructions refer only to new installations and installations that have been
frequently cleaned.
It is essential that frequent regular cleaning is undertaken to help prevent the growth of organisms
within the whirlpool system. The frequency of cleaning is dependent on the amount the system is
used. If the system is regularly heavily soiled it may need cleaning after every use.
Chemgene® / Trigene® is used in the diluted form for general disinfection of the bath surfaces only.
As an alternative, Chemgene® / Trigene® in its concentrated form it can be used for disinfection of
the whirlpool system as follows:
1.
Remove all cushions, supports, backrests and mattresses from the bath.
2.
Rinse any debris from the bath using a shower.
3.
Close drain by operating pop-up waste control
4.
Turn thermostatic mixer temperature setting to minimum.
5.
Fill bath with water to a level of 25mm (1” ) above the whirlpool jets.
6.
2100 Model add 2.5 litres (2500ml) of Chemgene® / Trigene® cleaner
1700/1900 Models add 2.2 litres (2200ml) of Chemgene® / Trigene® cleaner
2300 Model add 2.7 litres (2700ml) of Chemgene® / Trigene® cleaner
7.
Turn whirlpool aerator adjuster to minimum setting and run the whirlpool system for 20
minutes.
8.
Drain bath.
9.
Fill bath with clean water to 25mm (1”) above whirlpool jets
10.
Run whirlpool for 5 minutes.
11.
Drain bath
12.
Chemgene® / Trigene® is also recommended for general cleaning of the bath surfaces as per
instructions on the pack