Page 17 of 23
EASIBATH INSTALLATION
Your Kingkraft product should be only installed by competent installers. However, if you have to move
or re-install the bath for any reason, please take care to read the requirements given in the Pre-
Installation and Installation Instructions and the installation section below. Great care must be taken
not to damage the lifting column mechanisms if moving the bath. These are easily damaged if the bath
is lifted or slid from the original bath installation position incorrectly, never attempt to move the bath
when the columns are in an extended / raised position. Please contact Kingkraft for advice if you need
any further information or assistance.
Units with electrical services must only be wired in accordance with the IEE Wiring Regulations,
especially as regards zoning and equipotential bonding. Kingkraft products are intended for operation
only in a bathroom type location where exposed mains connections and unsealed switches etc. are
not permitted.
The unit must not be connected via a plug and socket
The power supply to the Easibath (if powered version) must be wired into the supply via an isolator
which supplies only the bath and must have double pole switching with contact separation of at least
3mm. If the isolator is not within sight of a person maintaining the bath unit, it must be lockable in the
‘off’ position.
We recommend that your Easibath is connected via a Residual Current Circuit Breaker (RCD/RCBO)
with an operating current of not greater than 30mA
With the exception of the control handset, all parts of the bath control system which are connected to
any electrical supply must be inaccessible to any person in the bath and must be fixed firmly into
position.
Take care to ensure that the floor on which the bath is to be placed can withstand the full weight of the
loaded bath (up to 500kg for standard specification Easibath).
Separate full Pre-Installation and Installation Instructions are available from Kingkraft.