OPERATION

COMPRESSOR WINE CELLAR

PAR

RANGE

DESCRIPTION

Preset Value

SCL

1°C;
2°C;
°F

Readout scale.
1°C (with 

INP

=SN4 only): measuring range  -50/-9.9 … 19.9/80°C

2°C :  measuring range   -50 … 120°C
°F :    measuring range   -55 … 240°F

Caution: upon changing the 

SCL

 value, it is then absolutely necessary to re-configure the parameters 

relevant to the absolute and relative temperatures (

SPL

SPH

SP

ALA

AHA

, etc..).

°F

SPL

-50..SPH

Minimum limit for 

SP 

setting.

41

SPH

SPL.120°

Maximum limit for 

SP 

setting.

64

SP

SPL... SPH Setpoint (value to be maintained in the room).

59

C-H

REF; HEA

Refrigerating (REF) or Heating (HEA) control mode.

REF

HYS

1...10°

OFF/ON thermostat differential

                            

Refrigerating control (

C-H

=REF)                                Heating control (

C-H

=HEA)

5

CRT

0...30min

Compressor rest time. The output is switched on again after 

CRT

 minutes have elapsed since the 

previous switchover. We recommend to set 

CRT

=03 with 

HYS

<2.0°.

6

CT1

0...30min

Thermostat output run when probe T1 is faulty. With 

CT1

=0 the output will always remain OFF.

3

CT2

0...30min

Thermostat output stop when probe T1 is faulty. With 

CT2

=0 and 

CT1

>0

  

the output will always be ON.

Example: 

CT1

=4, 

CT2

= 6: In case of probe T1 failure, the compressor will cycle 4 minutes ON and 6 

minutes OFF.

6

CSD

0..30min

Compressor stop delay after the door has been opened (active only if 

DS

=YES).

6

DFR 

 

0... 24(1/24h)

Defrost frequency expressed in cycles/24 hours.

3

DLI

-50...120°

Defrost end temperature.

39

DTO

1...120min

Maximum defrost duration.

20

DTY

OFF;
ELE;
GAS

Defrost type
OFF: off cycle defrost (Compressor and Heater OFF).
ELE: electric defrost* (Compressor OFF and Heater ON).

 

GAS: hot gas defrost* (Compressor and Heater ON).

* The defrost output is active if only 

OAU

=DEF.

OFF

DRN

0...30min

Pause after defrost (evaporator drain down time).

0

DDY

0...60min

Display during defrost. If 

DDY

=0 during defrost the temperature continues to be displayed. If 

DDY

 > 0, 

during defrost the display shows DEF, and at the end of defrost it shows REC for 

DDY

 minutes.

1

FID

NO/YES

Fans active during defrost.

YES

FDD

-50...120°

Evaporator fan re-start temperature after defrost.

32

FTC

NO/YES

Optimised fan control enabling. With 

FTC

 = NO the fans remain on all the time.

Fig. 2 Optimised fan control (

FTC

=YES)

YES

FT1

0...180sec

Fan stop delay after compressor stop. See Fig. 2.

180

FT2

0...30min

Timed fan stop. With 

FT2

=0 the fans remain on all the time.

1

FT3

0...30min

Timed fan run. With 

FT3

=0, and 

FT2

 > 0, the fans remain off all the time.

1

Summary of Contents for KBU-120S

Page 1: ...www kingsbottle com USER MANUAL KBU 25S SERIES COMPRESSOR WINE CELLAR LAE controller from Italy...

Page 2: ...ety instructions carefully to avoid misuse and hazards We recommend that you keep this instruction booklet for future reference and pass it on to any future owners After unpacking the appliance please...

Page 3: ...er reference The symbols you will see in this booklet have these meanings WARNING 6FGQ QWK MJ GLBGA RCQ GLDMPK RGML AMLACPLGLE WMSP NCPQML J Q DCRW CAUTION 6FGQ QWK MJ GLBGA RCQ GLDMPK RGML ML FMU RM...

Page 4: ...bottom hinges also screws for changing the door hinge Note Above diagram and description is for SINGLE ZONE WINE CELLAR MODELS KBU 25S series 1 Control board 2 Housing 3 Ventilation DC Fan 4 Sliding...

Page 5: ...ncluded stand height 0 98 25mm MODEL WIDTH DEPTH HEIGHT INCLUDED STAND HEIGHT NOTE KBU 25S 15 01 381mm 24 03 610mm 34 87 885mm 0 98 25mm Free standing model If you need to use as BUILT IN installation...

Page 6: ...old ambient temperatures may also cause the unit to perform improperly 5 Avoid locating the unit in damp areas 6 Plug the wine cellar into an exclusive properly installed and grounded wall outlet Do n...

Page 7: ...r between the appliance case and adjacent cabinet door swing PART III INSTALLATION INSTRUCTIONS INSTALLATION 1 5 mini 1 5 mini 1 5 mini Figure D Note This model is designed as free standing unit If yo...

Page 8: ...plugged into its own dedicated 220 240V 50Hz AC electrical outlet The plug must be accessible when the refrigerator is in position It is essential the power point is properly earthed to ground Consult...

Page 9: ...commended to tape down shelves to avoid movement during the process It is recommended to take out the wine bottles from the cellar before reversing the door PART III INSTALLATION INSTRUCTIONS INSTRUCT...

Page 10: ...3 and 4 6 Wipe off any dust that has accumulated during shipping and clean following the directions in Part VIII Care Maintenance 7 Plug the appliance into the power point Don t use a double adaptor o...

Page 11: ...ng E2 Probe T2 failure DO Door open alarm INFO MENU The information available in this menu is T1 Instant probe 1 temperature TLO Minimum probe 1 temperature recorded T2 Instant probe 2 temperature CND...

Page 12: ...ed to obtain the defrosting frequency set with DFR IIDF For example with DFR 4 defrosting occurs once every 6 hours The internal timer is set to zero when power is applied to the controller and at eac...

Page 13: ...s be ON Example CT1 4 CT2 6 In case of probe T1 failure the compressor will cycle 4 minutes ON and 6 minutes OFF 6 CSD 0 30min Compressor stop delay after the door has been opened active only if DS YE...

Page 14: ...lowing parameter will be SB MAN button switches the two parameter groups over NON IISL 50 IISH Minimum limit for IISP setting 41 IISH IISL 120 C Maximum limit for IISP setting 64 IISP IISL IISH Setpoi...

Page 15: ...ach compartment will return to the previous temperature setting 2 If the unit is unplugged loses power or is turned off you must wait over 6 minutes before restarting Within this 6 minutes compressor...

Page 16: ...tom 2 Also make sure that bottles are not all grouped together either at the top or bottom of the cabinet 3 Never try to pull out more than one rolling shelf at a time 4 Maximum capacity per shelf is...

Page 17: ...NG 4 4 4 4 06 9 40 0 This appliance may contain a small quantity of environmentally friendly but flammable non synthetic R600a refrigerant s NSURE THAT THE TUBING OF THE REFRIGERANT CIRCUIT IS NOT dam...

Page 18: ...h air circulated fan cooling CLIMATE TYPE N ELECTRICITY PROTECTION GRADE I NOMINAL VOLTAGE FREQUENCY 110 115V 50 60HZ RATED POWER W 120W AMBIENT TEMPERATURE 32 100 F TEMPERATURE RANGE 41 64 F NET WEIG...

Page 19: ...www kingsbottle com 19 NOTES COMPRESSOR WINE CELLAR...

Page 20: ...he limited warranty does not cover Damage due to such things as accident misuse abuse mishandling neglect unauthorized repair or any other cause beyond the control of the seller whether similar or dis...

Reviews: