background image

standards for such appliance. We will always do its utmost to satisfy its customers but will not 
retake possession of the goods due to complaints based on normal operating noise occurrences.

STARTER -TIPS 

1. Clean the inside of the Steak Ager with disinfectant, which shouldn’t be aggressive. 

2. If ordered: unpack the salt blocks and remove the foil. Put the salt blocks in the stainless steel 
tray and place the tray at the bottom of the cabinet. Please check every 2-3 days if there is any 
remaining water on the salt blocks, if so, please remove the water.

3. The temperature and humidity are already setted on 1

 (34°F) and 85% humidity which are 

the perfect setting for dry aging beef & pork.

4. The meat for the dry aging must be fresh, perfect would be max.5 days after slaughtering. 
Even vacuum matured meat can be used, but for a maximum of 14 days (please remove foil)

5. Our recommendation for the best dry aged beef: use meat from a young cow with an ordinary 
fat cover plus good marbling.

6. Hang the complete back on the hangers of your Steak Ager or put the individual cuts on the 
shelves.

7. Load capacity: max.2x half strip loins on the bone with a length of 0.5m, therefore you will 
need 2 hangers.

8. Load capacity with shelves: max.20kg individual pieces or cuts will fit on our shelves.

9. When maturing individual cuts on the shelves, pay attention on a protective fat layer which 
prevents too much wastage and if possible let it mature on the bone. Ideal size aprox.2-4 kg / 
cut.

10. Please wear protective gloves at each contact with the meat, DON’T touch the meat without 
gloves!

11. The perfect maturing time is between 25-28 days, but more than 4 weeks is also possible.

TEMPERATURE SETTINGS 

IMPORTANT:  THE LED DISPLAYS BY DEFAULT THE ACTUAL INTERNAL AIR TEMPERATURE. 

The temperature settings are pre-set at the factory as follows. In the event of a power 
interruption, all previous temperature settings are automatically erased and it will revert to the 
preset temperature settings.

The electrical board of all models comes with memory function.

It is important to understand that there is a di

erence between the temperature inside the Steak 

Ager and the temperature shows on display panel: You will need to wait approximately 12 hours 
before noticing the e

ects of temperature adjustment if the steak ager with full loading.

Once the temperature is set, please don’t adjust it frequently. The thermostat will maintain the 
temperature inside the Steak Ager within a +/- 2.5°C (4.5ºF) (range. But the thermal inertia of the 

 

11

Summary of Contents for KBU120SA

Page 1: ...vanced products will give your meat a di erent and pleasant taste Before use please read and follow all safety rules and operating instructions 1 USER MANUAL KBU 50 180SA STEAK AGER FRIDGE The model n...

Page 2: ...APPLIANCE IS ONLY SUITABLE FOR THE COOLING OF MEAT OR FOOD IN COMMERCIAL ENVIRONMENT OR SIMILAR All other types of use are not permitted Any misuse of the appliance may result in damage to the stored...

Page 3: ...R600a WARNINGS For your safety observe the following recommendations This appliance contains a small quantity of R600a refrigerant which is environmentally friendly but flammable It does not damage t...

Page 4: ...iance WARNING Do not use extension cords or ungrounded two prong adapters WARNING If the supply cord is damaged it must be replaced by the manufacturer Its service agent or similar qualified person in...

Page 5: ...electrical outlet Note In locations where there is frequent lightning it is advisable to use surge protectors Improper use of the grounding plug can result in the risk of electric shock Consult a qua...

Page 6: ...ght side at the back when looking from front of cabinet 7 As with most appliances of today the Steak Ager has sensitive electronic components which are susceptible to damage through lightning and elec...

Page 7: ...RAWINGS FOR BUILT IN STEAK AGER UNDER BENCH FRONT VENTING STEAK AGER ONLY Note The appliance must be positioned so that the plug is accessible after installed DIMENSIONAL DRAWINGS KB50SA KBU50SA KB120...

Page 8: ...KB180SA KBU180SA 8...

Page 9: ...OPEN ANGLE SIZE DRAWINGS KB50SA KBU50SA KB120SA KBU120SA KB180SA KBU180SA 9...

Page 10: ...wer is lost or turned off wait 3 to 5 minutes before restarting the unit The Steak Ager will not start if you attempt to restart before this time delay OPERATING NOISES To reach the desired temperatur...

Page 11: ...0 5m therefore you will need 2 hangers 8 Load capacity with shelves max 20kg individual pieces or cuts will fit on our shelves 9 When maturing individual cuts on the shelves pay attention on a protect...

Page 12: ...o Press again without delay the power turns on UV system control instruction 1 Automatic control The machine is power on If the UV light doesn t be turned on by human the UV light will turn on for eve...

Page 13: ...enheit LCD DISPLAYER OPERATION GUIDE Power Switch Function Keys Lamp Fahrenheit Celsius change Keys Temperature Humidity setting down Temperature Humidity setting up UVC Lamp Humidifying Dehumidificat...

Page 14: ...n o 3 When the UV light turn on the UV light will be closed when door is open and it will be on when door is closed Note The life of the UV lamp is 12 months Exceeding the service life will greatly re...

Page 15: ...r container provided with your Steak Ager All units are equipped with a double layers Low E glass door that has a third internal acrylic layer to minimize condensation on the glass door The Steak Ager...

Page 16: ...ll display E5 indicates a water shortage fault and the light will flash when this fault occurs The following is a schematic diagram of the addition of water 1 First press the arrow to open the water t...

Page 17: ...ned to the maximum angle 2 Use small knife 2 to take o the decorative nail 1 on opposite side Drawing 1 3 Use the inner six angle screwdriver Tool 5 to disassemble the screws 4 of drop proof device 3...

Page 18: ...out handle from cabinet then take out 4pcs 4 35 screws from accessory bag 2 Pull open door seal from the side of door then insert screws into the 2 handle holes on side of door then put the screws ali...

Page 19: ...e result It is always recommended to buy a piece of meat that has a good fat content and a high rate of internal marbling It is advisable to mature the meat on the bone either hanging or in the larges...

Page 20: ...id POWER FAILURES In the event of a power interruption all previous temperature settings are automatically preservation and it will revert to a preset temperature setting See preset chart Most power f...

Page 21: ...d too often The door is not closed completely The temperature control is not set correctly The door gasket does not seal properly The light does not work Not plugged in The circuit breaker tripped or...

Reviews: