background image

Press

key to view CT and ET temperature mode.

Press

to change the viewing of CT setting from ET setting or

press

key to change the viewing of ET setting from CT setting.

The temperature is flashing at this moment. Press

or

key to change CT or ET setting. Press

key to confirm the

setting and return to running mode.

To set temporary manual override temperature:

This function allows you to change the present temperature
setting to a temporary temperature setting from next

1

hour up

to

48

hours. Press

or

to enter the manual override

temperature mode and temperature is flashing.
Press

or

key to select override temperature. Press

key to

confirm temperature setting. H will display and flash.
Press

or

key to select hours for overriding time.

The maximum hours are

48

. Press

key to confirm setting.

To cancel manual, temporary, vacation or permanent

override:

Press

or

key to return into running mode. Or press

key

to turn off the unit.

To switch the unit ON and OFF:

Press

key to turn off from on. Press

key to turn on from off.

To reset the unit:

Press the Reset key to reset the unit into initial clock setting
mode. All previous programs will reset to factory preset
settings.

User Optional Selection:

On the back of the front housing there is a DIP SWITCH on the
PCB where the user can select following option:

To set temporary override program temperature:

This function allows you to temporarily override the CT
temperature from the ET temperature settings, until next CT
setting (or vice versa).

Program temperature setting until next ET setting.
The unit is running at CT program period. Press

to change

from CT to ET setting (until the next CT program period).
The unit is running at ET program hour. Press

to change

from ET to CT setting (until next ET program hour).

Note: The first hour of override (

1

H) will only run for maximum

45

minutes. However from second hour onward will run for full

hour timing. e.g. If you select

2

hours override the maximum

time of override will be

1

hour and

45

minutes.

To set vacation or permanent override temperature:

This function allows you to set your vacation temperature from

1

to

99

days or to set a permanent override temperature forever.

Press

key will display under “SA SU” and flash. Press

or

key to select the number of day for your vacation period.

DIP SWITCH 1 - SWING CYCLE -

ON

=

0.2

°

C

OFF

=

0.5

°

C

DIP SWITCH 2 - HEATING OR AIR-CONDITIONING

System setting

ON = AIR CONDITIONING
OFF = HEATING

Sensor:

This thermostat (THPW

1

-C*) uses the most advance

temperature sensing element located on the lower right side of
the cast under the grill. If the sensor is touched accidentally you
must allow few minutes for sensor to come back to normal
temperature.
The temperature is measured every minute.

Note that if you connect the receiver to a

230

V AC system,

please make sure the power is switched off and that only a
person with good electrical knowledge carries out the
installation. This receiver has a volts free contacts.
If you have a mechanical receiver connected with

2

wires just

take away the old receiver and replace it with THPW

1

-C* re-

ceiver. Connect the wires to the terminals as shown in Fig

5

.

Note: The base unit of this product must be mounted within a
suitable enclosure. Base unit is DIN rail mountable.

Receiver should be mounted on a wall close to the boiler and
within

50

m of the THPW

1

-C* thermostat transmitter.

Receiver should be mounted on a

65

mm long section of DIN

rail within a suitable enclosure. Red “on” indicator illuminates
when the “heat on” indicator is showing on the THPW

1

-C*

thermostat transmitter.

230

V AC input supply to THPW

1

-C* receiver should be from a

switched spur unit fused at

3

Amps.

THPW

1

-C RECEIVER INSTALL

INPUT

THPW

1-

C Receiver

Red

“on” indicator

L

230

VAC

(Receiver Supply)

AC feed

16

Amp

Max

N

N in

N out

Fig

5

Temperature range:

5-30

°C

Differential:

+/-

0.5

°C from set temperature

Temperature accuracy:

+/-

0.5

°C

Batteries:

2

x AA (

1.5

VDC) size batteries

Receiver Rated switching

230

V,

50Hz

AC,

16

A resistive

power:

2

A Inductive load

Minimum on time in
heating mode:

1

minute

Minimum off time in
air-conditioning mode:

3

minutes

RF Frequency:

433

MHz

Is

s

u

e

n

o

:

7

0

2

9

6

6

The maximum selection is up to

99

days. If you choose - - the

period will be permanent override. Press

key to confirm the

vacation period.
Press

or

key to select temperature. Press

key to confirm

the override setting.

TECHNICAL INFORMATION