background image

Gas Conversion for FP2085T and FP2785T Fire Pits 

NOTE: CONVERSION SHOULD BE COMPLETED BEFORE FIRE PIT IS INSTALLED. 

Caution- the gas supply shall be shut off before proceeding with the conversion. 

 

 

TO CONVERT PROPANE (MAP) SYSTEMS TO NATURAL GAS: 

1.  Remove [2] screws from Orifice Retainer Bracket. 
2.  Remove Burner Orifice from Air Shutter. Using a 1/2” wrench, 

disconnect Burner Orifice from brass fitting and replace with 

supplied 

#15

 NG Burner Orifice. 

3.  Set Air Shutter Adjustment to 

1/4”

4.  Re-insert new Burner Orifice into Air Shutter.  
5.  Re-attach Orifice Retainer Bracket to Burner Tray. 
6.  Disconnect LP Hose and Regulator from Valve Assembly. 

TO CONVERT NATURAL GAS (MAN) SYSTEMS TO PROPANE: 

1.  Remove [2] screws from Orifice Retainer Bracket. 
2.  Remove Burner Orifice from Air Shutter. Using a 1/2” wrench, 

disconnect Burner Orifice from brass fitting and replace with 

supplied 

#38

 LP Burner Orifice. 

3.  Set Air Shutter Adjustment 

Fully Open

4.  Re-insert new Burner Orifice into Air Shutter.  
5.  Re-attach Orifice Retainer Bracket to Burner Tray. 
6.  Connect LP Hose and Regulator to Valve Assembly. 

 

 

 

WARNING 

This conversion kit shall be installed by a qualified service agency in accordance with the 

manufacturer’s instructions and all applicable codes and requirements of the Authority 

Having jurisdiction. If the information on in these instructions is not followed exactly, a fire, 

explosion or production of carbon monoxide may result causing property damage, 

personal injury or loss of life. 

The qualified service agency is responsible for the proper installation of this kit. The 

installation is not proper and complete until the operation of the converted appliance is 

checked as specified in the manufacturer’s instructions supplied with the kit. 

5ft LP Hose & Regulator 

PN: 27FP-900FF 

 

Burner Orifice: 

#15 for Natural Gas 
#38 for Propane 

Air Shutter Adjustment: 

1/4” for Natural Gas 
Fully Open for Propane 

WARNING: 

Failure to position the parts in accordance with these 

diagrams or failure to use only parts specifically approved with 

this appliance may result in property damage or personal injury.

 

Orifice Retainer 

Bracket 

11

Summary of Contents for FP2085LPT

Page 1: ...Use Only Installation and service must be performed by a qualified installer service agency or the gas supplier WARNING If the information in this manual is not followed exactly a fire or explosion may result causing property damage personal injury or loss of life DANGER CARBON MONOXIDE HAZARD This appliance can produce carbon monoxide which has no odor Using it in an enclosed space can kill you N...

Page 2: ...ly and its operation including remote control operation if included is fully explained to and understood by the customer Important Information About Outdoor Fireplaces Before you build in this appliance Do not insulate around the appliance Heat buildup could lead to component failure Pay attention to all clearances to combustibles and specifications stated in this manual Drainage If this appliance...

Page 3: ...mponent List 12 FP2785T Component List 13 Log C85 Placement Instructions 14 Accessories for Your Fire Pit Bola Fire Bowls 15 24OBT MANCP Control Panel for FP2085T Fire Pits in Custom Enclosures 16 FP20SSRT Stainless Steel Ring Dimensions Accessory for FP2085T Round Fire Pit 17 FPB30TRG Trim Ring Dimensions Accessory for Fire Bowl 17 Product Maintenance for Your Canvas Fire Pit Cover 18 Stainless S...

Page 4: ...replaced prior to operating the appliance 11 Installation and repair should be done by a qualified service person The appliance should be inspected before use and at least annually by a professional service person More frequent cleaning may be required due to excessive lint from carpeting et cetera It is imperative that control compartments burners and circulating air passageways of the appliance ...

Page 5: ... Within a partial enclosure that includes an overhead cover and no more than two side walls 3 These side walls may be parallel as in a breezeway or at right angles to each other 4 Within a partial enclosure that includes an overhead cover and three side walls as long as 30 percent or more of the horizontal periphery of the enclosure is permanently open All models can be installed safely in a scree...

Page 6: ...n minimum enclosure dimensions of 32 1 2 x 39 1 2 I D The top of enclosure must be of a non combustible material such as concrete board or wonder board 2 Clearance to combustible side wall is 24 minimum Non combustible walls 14 to side wall 3 Minimum clearance to any combustible ceiling with no overhang is to be 7 feet from top of firepit 4 Clearance to a combustible floor is 0 FP2785T in a combus...

Page 7: ...nish on top of Wonder Board Do not use any combustible materials to finish top e g wood or plastic products 4 You must have an opening in the enclosure to have access to the on off valve 5 A minimum of 2 1 x 4 air openings are required Minimum Opening Minimum Size for FP2785T Combustible Enclosure Combustible materials may be used only on outer portion of cabinet Metal Gussets Control Panel Cutout...

Page 8: ... D Inside corners of shields should not touch combustible wall Shield must extend 3 past end of firepit Fig 1 Ref E 4 Note Firepit cabinet or other structures must NOT obstruct wall shield air space on ends top or bottom If a cabinet is built around firepit the end face of cabinet must not extend past bottom face of clearance shield by more than 1 2 Fig 2 Ref D SINGLE CLEARANCE SHIELD 1 Side of un...

Page 9: ...be and make sure it is tight NOTE Fuel Supply line must not come into contact with surfaces having temperatures in excess of 140 F LP gas cylinder must be kept a minimum of 4 5 feet from the appliance You must use an approved LP cylinder retention device See Gas Specifications for an example 5 When connecting regulator assembly to the tank valve hand tighten nut clockwise to a positive stop DO NOT...

Page 10: ... be opened without the use of tools Designs using a cover to gain access to the cylinder and cylinder valve shall be provided with handles or equivalent at a minimum of 180 degrees apart to facilitate lifting of the cover The enclosure for the LP gas cylinder shall isolate the cylinder from the burner compartment to provide a Shielding from radiation b A flame barrier and c Protection from foreign...

Page 11: ...ifice into Air Shutter 5 Re attach Orifice Retainer Bracket to Burner Tray 6 Connect LP Hose and Regulator to Valve Assembly WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer s instructions and all applicable codes and requirements of the Authority Having jurisdiction If the information on in these instructions is not followed exactly ...

Page 12: ...osition the parts in accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 15 BRASS CAP ORIFICE PRIMARY AIR 1 4 NATURAL GAS 38 BRASS CAP ORIFICE PRIMARY AIR FULL OPEN PROPANE 5ft LP Hose Regulator 27FP 900FF 12 ...

Page 13: ... accordance with these diagrams or failure to use only parts specifically approved with this appliance may result in property damage or personal injury 15 BRASS CAP ORIFICE PRIMARY AIR 1 4 NATURAL GAS 38 BRASS CAP ORIFICE PRIMARY AIR FULL OPEN PROPANE 5ft LP Hose Regulator 27FP P900FF 13 ...

Page 14: ...up the gas connection make sure that logs are not broken Identify the logs using the pictures below and place logs as indicated lining up with mounting pegs in logs STEP 1 STEP 2 STEP 3 STEP 4 STEP 5 This picture depicts the typical flame pattern of this burner system 14 ...

Page 15: ...1 1 2 holes for drainage Fire Pit Bowl for FP2085T Round Fire Pit Valve Igniter Mount Box KINGSMAN OUTDOOR FIRE BOWLS FOR THE 2085T FIRE PIT Fire Bowl Includes Valve Igniter Mount Box 1 4 Lava Rock 10 Lbs Leg Extension Filler Strip Ring SS Flex Connector Fire Pit not included FPB32SGT Fire Bowl 32 Diameter Concrete Smooth Grey T Series 30FPB KEYT Key Way Valve Kit for New Thermocouple Fire Bowls f...

Page 16: ...he Valve Control Panel is 2 7 16 tall x 7 1 2 wide The Control Panel is inserted from the inside of the enclosure and set in place by tightening the 2 screws on the back of the Control Panel Assembly Burner Orifice Control Panel BOTTOM VIEW CUSTOM ENCLOSURE CUTOUT RIGHT SIDE VIEW Tighten Screws to secure Manual Valve Control Panel RIGHT SIDE VIEW Tighten Screw Tighten Screw 16 ...

Page 17: ...FP20SSRT Stainless Steel Ring Dimensions Accessory for FP2085T Round Fire Pit FPB30TRG Trim Ring Dimensions Accessory for Fire Bowl 17 ...

Page 18: ...tly mist the surface every 6 months to check the water repellency Friction will wear away product more quickly leaving the fabric unprotected If this is the case such areas can be spot treated to renew repellency Just a note Silicone water repellents are not true fabric protectors While they do develop good repellency they often retain a tackiness that attracts dirt Silicone treated fabrics soil m...

Page 19: ...BAGS 30 35LBS 6 7 BAGS MQG5B 1 2 Black Glass 5LBS 20LBS 4 BAGS 20LBS 4 BAGS 30 35LBS 6 7 BAGS MQG10C 1 4 Reflective Bronze Glass 10 LBS 20LBS 2 BAGS 20LBS 2 BAGS 30 35LBS 3 4 BAGS MQG10B 1 4 Black Glass 10 LBS 20LBS 2 BAGS 20LBS 2 BAGS 30 35LBS 3 4 BAGS Media Examples Shown Below FP2085T Without Media Lava Rock 1 Bag 10LBS MEDIA REQUIREMENTS OPTIONS When not using LOGC85 Log Set 20 LBS of Glass Re...

Page 20: ...ava Rock Supplied with Fire Pit 1 4 Lava Rock is used as Base Reflective Bronze Glass 20LBS MQSTONE with Lava Rock Base 10LBS MQSTONE with Bronze Glass Base 20LBS NOTE MQSTONE Requires a Glass or Lava Rock Base 20 ...

Page 21: ...lso examine the area around the burner air shutter Any dirt or lint in this area should be removed This will ensure long life and trouble free operation Re install the logs as shown in the log placement instructions When the appliance is put back in service check the burner flame patterns with Log Placement Instructions Section 5 Periodically check the hose connecting the LP gas cylinder to ensure ...

Page 22: ...S Do not try to light any appliance Do not touch any electric switch do not use any phone in your building Immediately call your gas supplier from a neighbor s phone Follow the gas supplier s instructions If you cannot reach your gas supplier call the fire department Manual Valve with Push Button Ignition 1 STOP Read the safety information above 2 Remove the top cover 3 Find the manual gas control ...

Page 23: ...ss Steel Flex Connector 16 Qty 2 for FP2085NT Qty 1 for FP2085LPT 3 8 Stainless Steel Flex Connector 10 Qty 1 for FP2785LPT FL 8 24OB PHP1003 Thermocouple 9 4000 P963VE 3 8 Tube OD x 3 8 Male Pipe 10 27FP P900FF LP Reg 5ft Hose I4T60GRQC Only supplied with FP2085LPT FP2785LPT FL 11 24OB 102 Orifice Retainer Bracket 12 24OB P152 Push Button Igniter AAA Battery not included 13 24OB 107A Electrode Wi...

Page 24: ...307 Flat Lid for FP2785T FP20SSRT Stainless Steel Ring Fits FP2085NT FP2085LPT 24OBT MANCP Control Panel for FP2085NT FP2085LPT Round Fire Pits in custom enclosures OUTDOOR FIRE BOWLS FOR THE 2085T FIRE PIT Fire Bowl Includes Valve Igniter Mount Box 1 4 Lava Rock 20 Lbs Leg Extension Filler Strip Ring and SS Flex Connector Fire Pit not included FPB32SGT Fire Bowl 32 Diameter Concrete Smooth Grey T...

Page 25: ...and or handling charges associated with any repair or replacement pursuant to this limited warranty will be your responsibility In this warranty the word installation means original installation We will not be responsible for and you the user will pay for a damages caused by accident abuse negligence misuse riot fire flood or Acts of God b damages caused by operating the unit where there is a corr...

Reviews: