FP2085T & FP2785T - Assembly and Installation
The log set (LOGC85) and the burner assembly are shipped
separately.
A.
Remove the gas log set and burner assembly and check
for damage. DO NOT install damaged components. The
logs are fragile use care when handling.
B.
Place the burner assembly on a flat, stable surface in an
outdoor location such as a patio or a deck. This location
must be adjacent to the gas supply line (natural gas) or
LP-gas supply cylinder.
NOTE
: Minimum clearances to combustible construction
must be maintained. Remember, you must have easy
access to the gas valve control knob AFTER the
appliance is installed and connected to the gas supply.
THE ON/OFF GAS VALVE IS USED TO TURN THE
BURNER ON AND OFF.
C.
NATURAL GAS MODELS: Connect the incoming gas
supply line to the on/off gas valve of the appliance (Figure
1). Make certain ALL gas connections are tight, turn the
on/off valve at the unit slowly to the on position and use
soap water to test for leaks. DO NOT USE AN OPEN
FLAME.
LP-GAS MODELS:
1. Make sure tank valve is in its full off position. (Turn
clockwise to stop).
2. Check tank valve features to ensure it has proper external
mating threads (Tank Valve Marked: USE WITH TYPE 1).
3. Inspect hose shipped with the unit for damage. Never
attempt to use damaged or plugged equipment. See your
local LP Gas Dealer for repairs.
4. After inspecting the LP hose shipped with the unit,
connect the end with the female fitting on the hose to the
male fitting on the on/off gas valve at the end of the flex
tube and make sure it is tight.
NOTE: Fuel Supply line must not come into contact with
surfaces having temperatures in excess of 140°F. LP gas
cylinder must be kept a minimum of 4.5 feet from the
appliance. You must use an approved LP cylinder
retention device (See Gas Specifications for an example).
5. When connecting regulator assembly to the tank valve,
hand tighten nut clockwise to a positive stop. DO NOT
use a wrench to tighten. Use of a wrench may damage
quick closing coupling nut and result in a hazardous
condition.
6. Locate the hose out of pathways where people may trip
over it or in areas where the hose may be subject to
accidental damage.
7. Open tank valve fully (counter-clockwise). Turn the on/off
valve at the unit slowly to the on position and use a soapy
water solution to check all connections for leaks before
attempting to light the appliance. If a leak is found, turn
tank valve off and do not use the appliance until repairs
can be made by a local LP Gas Dealer. DO NOT attempt
to make repairs yourself.
8. Never attempt to use this appliance or any components
that have been damaged or exposed to an accidental fire.
Gas Specifications
FP2085NT
FP2085LPT
FP2785NT
FP2785LPT
Fuel
Natural Gas
Propane
Minimum Supply Pressure
7” w.c.
10” w.c. - Hose Regulator
Maximum Supply Pressure
7” w.c.
10” w.c. - Hose Regulator
Manifold Pressure Low N/A
N/A
Manifold Pressure High N/A
N/A
Btu’s 13,000Lo
57,000Hi
22,500Lo
64,000Hi
Orifice #15
#38
Air Shutter Opening 1/4”
Fully Open
The above photo shows an
example of an approved LP
cylinder retention device.
⚠
WARNING:
DO NOT LEAVE
FIRE PIT UNATTENDED
WHEN IN USE
WARNING
TIPPING HAZARD
Tank must be
secured
PROPANE
CYLINDER
WITH
TYPE 1 FITTING
FIREPIT
ASSEMBLY
9