Fireplace Installations in Covered Outdoor Locations
– FOR BASIC MILLIVOLT UNITS ONLY- NO FAN – NO LIGHTS-
Kingsman and Marquis Direct Vent fireplaces may be installed into outdoor locations provided they are suitably protected
from direct water impingement.
However, all installation clearances in the appliance manual must be observed. Framing,
Clearances to Combustibles, Mantel Heights, Facing Requirements, Venting Installation, etc.
Use supplied Safety Screen.
All wiring connections to line power shall be in accordance with outdoor requirements of; -NECA NFPA 70 in the USA
-Canadian Electrical Code, CSA C22.1 for Canada.
The Fireplace is not to be operated in temperatures below freezing (0°C / 32°F).
⚠
NOTE: TEMPERED GLASS WARNING:
Tempered glass is vulnerable to rapid and/or extreme changes in
temperature (thermal shock). Take care to prevent water from contacting the fireplace, especially if it is hot.
See-Through Units are suitable for an outdoor location, but not on the outside wall of a house or other structure, as
air flows through both sides of the fireplace.
A Minimum sheltering cover (overhang) of 1/2 the distance from the base of the fireplace to the ceiling (base of
roofline) is required
.
EXAMPLE:
The bottom of the fireplace is 84” from the ceiling.
Therefore, 42” of sheltering cover is required above fireplace.
CAUTION – Installation of an indoor gas fireplace with an outdoor exposure is not covered under the (ANSI
Z21.88 – CSA 2.22 or ANSI Z21.50 – CSA 2.33) standard(s) used to certify the indoor gas-fired fireplace. The
Intertek safety certification will not apply to this installation method. This installation method must be deemed
acceptable by the Authority Having Jurisdiction (AHJ) prior to the indoor gas fireplace being installed.
OUTDOOR
AREA
Glass
Door
Glass
Door
Glass
Door
Outside Wall
of House
8