IDV26
Burner Installation/Removal
Remove glass door assembly and logs (if installed). Be
careful with logs as they become fragile after being
heated.
Remove log supports from burner assembly.
The burner can now be removed.
TO REMOVE H-BURNER/ORIFICE CHANGE -
Remove
the two [2] screws holding the H-Burner in and slide it
leftwards off the orifice.
TO REMOVE ENTIRE BURNER ASSEMBLY
, see
below.
Step 1:
Disconnect pilot lines and gas supply line from
valve on the side of the unit.
NOTE: Care should be
taken to ensure that the gas and pilot lines are not
damaged during handling. These lines are fragile.
Step 2:
Locate and remove the twelve [12] screws around
the outside of the burner pan. This will remove the entire
burner assembly.
To reinstall the burner assembly ensure the surfaces are
cleaned, and old sealant material removed. Use high temp
Millpac to seal and secure with the twelve [12] screws.
Pilot Removal
Disconnect pilot lines from valve as shown above.
Remove fan access panel (Not necessary to remove fan)
and use this space to draw pilot out from unit.
Installation is the reverse of these steps. Reseal pilot
connections to burner pan with orange silicone.
Valve Removal
Disconnect pilot lines and gas supply line from valve on the
side of the unit.
NOTE: Care should be taken to ensure
that the gas and pilot lines are not damaged during
handling. These lines are fragile.
Remove [2] 3/8” nuts holding valve onto Component Plate.
Unhook valve from Component Plate.
⚠
CAUTION
Before servicing the burner system ensure that the gas supply is turned OFF and disconnect all electrical connections
to the appliance. Allow the appliance to cool to room temperature. Note that the pilot assembly may be hot in an
intermittent or standing-pilot system—even if the main burner was never on. Exercise caution when working within the
area. ALL WORK SHOULD BE PERFORMED BY A QUALIFIED AND CERTIFIED TECHNICIAN.
Fan Access Panel Removed.
31
Summary of Contents for Marquis IDV26
Page 15: ...I26SU UNIVERSAL SURROUND I26CVPF1 or I26CVPF3 I26CVPF2 or I26CVPF4 BOTTOM OF UNIT 15 ...
Page 45: ...I43CV I43CV3 I43US4736 Flat Custom Surround TO BE CUSTOM CUT AND BENT I43CV I43CV3 7 1 4 45 ...
Page 89: ...Gas Conversion for Modulator PART C 89 ...
Page 100: ...Proflame 2 Remote Control 100 ...
Page 102: ...102 ...