IDV26 / IDV33 / IDV43
Wall Coverings
All wall coverings below
Combustible Mantel Line
MUST
be Non-Combustible
(e.g. steel studs and
concrete board).
All wall coverings
closer than
Combustible
Materials Line
MUST
be NON-
Combustible.
*To reduce height of
Combustible Mantel see
Mantel Clearance Shield
section.
*For more information see
Clearance to Combustible
Mantels
Page.
CV Surround
(IDV26 This Side Only)
(IDV26 This Side Only)
(IDV26 This Side Only)
Required Minimum Hearth
IDV26
– 3/4” x 12-1/2” x 31” wide
IDV33
– 3/4” x 10” x 31” wide
IDV43
– 3/4” x 10” x 35” wide
NOTE: Floor Under Appliance Must
Be Non-Combustible
67