33
The Kingspan Environmental Solar Thermal product range offers both a single stream and a
dual stream pump station.
The maximum flow rate required on a system is typically 1 litre per minute, per square metre
installed for systems up to 12m
2
.
Pump Station
Key
1 Drain connection
2 Fill connection
3 Flow meter
4 Isolating valve
5 Motorised pump
6 6 bar pressure relief valve
7 Expansion vessel connection
8 Pressure gauge
9 Pipe connections
10 Temperature gauge
11 Air separator (dual stream only)
12 Insulated fascia
13 Pressure relief discharge point
6
8
7
5
3
2
1
1
2
4
5
7
8
9
9
6
11
12
13
13
10
12
4
3
10
9
9
Dual Stream
Single Stream