Varisol Installation Manual
10
This roof kit may be used to secure directly
through tile or slate surfaces.
To convert this roof kit to meet mcs012
requirements please use bolt down seals
(KSK0315) available separately.
KSK0234
(10) Varisol Bolt Down Kit
KSK0235
(20) Varisol Bolt Down Kit
KSK0236
(30) Varisol Bolt Down Kit
Bolt Down Roof Kit
1. Locate the rafters beneath the roof
material and drill pilot hole of ø
8mm to a depth of approx. 120 mm
3. Screw the bolt in the rafter using spanner if required, locate the nut above
the seal rubber and tighten to provide good seal with fixing surface.
When using mcs seal (KSK0315) tightening is not required. Attach the rails
using M8 x 20 bolts provided.
2. Drill a hole in the tile/slate in
recommended size
Complete Roof
IMPORTANT:
IT IS REQUIRED THAT 1ST, LAST AND
AT LEAST EVERY TENTH TUBE IN THE SYSTEM IS
SECURED TO THE RAIL WITH M8 X 16 BOLTS PROVIDED
1400–1700mm
400–600mm (10)
600–1000mm (20)
800–1400mm (30)