DE90i-S, Rev. A00
Kingston Technology Company
Appendix B - Specifications/Dimensions
17
Appendix B - Specifications/Dimensions
SCSI Data Express subsystems conform to the Small Computer Systems Interface (SCSI)
Standard set by the American National Standards Institute (ANSI).
Environmental Specifications
Operating
Storage
Ambient Temperature
-5° C to 45° C
-20° C to 60° C
Relative Humidity
(1)
10% to 80%
10% to 90%
Altitude
-1000 to 50,000 ft
-1000 to 50,000 ft
-304m to 15240m
-304m to 15240m
Shock
(2)
10g
60g
(1)
Non-condensing with maximum Gradient of 10% per hour.
(2)
11 msec Pulse Width 1/2 Sine Wave.
Physical
Specifications
Carrier
Receiving Frame
Height
1.680" (42.7mm)
1.700" (43.2mm)
Width
4.625" (117.5mm)
5.735" (145.7mm)
Depth
8.020" (203.71mm)
8.700" (221.0mm)
Weight
.8lbs. (.36kg)
(1)
.6lbs. (.27kg)
(2)
(1)
Plus weight of installed disk drive.
(2)
With carrier removed.
Chassis Reliability/Maintainability
MTBF
500,000 Hours
MTTR
5 Minutes
Preventive
Maintenance
None
Electrical Specifications
Input
+5V
50mA
+12V
0mA
Summary of Contents for DATA EXPRESS DE90