background image

DE100i-A100 User's Guide - Rev. C02

StorCase Technology, Inc.

Installation

7

Figure  6:    Drive  Carrier  Circuit  Board

INSTALLATION

Installing the Drive into the Carrier

NOTE:

A #2 Phillips screwdriver will be required during this procedure.

While performing the steps in this section, work on a soft surface to prevent excessive shock

to the drive being installed.  Also refer to the manufacturer's documentation provided with the
drive.

1.

Remove the drive from its protective packaging.

2.

Plastic Drive Bezel:

  If the drive came equipped with a plastic front bezel, it must

be removed before installing the drive into the drive carrier.

3.

Master/Slave Drive Selection:

  In most cases, the drive will be factory-configured

as a Master Ultra ATA133 drive using a jumper plug on the drive itself.  No con-

figuration changes are required.  For multiple drive configurations, it is necessary

to set the first Ultra ATA133 drive as Master and the second Ultra ATA133 drive to

Slave.  This can be done by changing the jumper on the Ultra ATA133 drive itself

(refer  to  your  drive  manufacturer  documentation  for  further  information).

Drive  Activity  Indicator  Connector  J5  (Drive  Carrier  Circuit  Board)

Jumper removed (factory default) disables drive activity indicator (Figure 4).

Jumper installed enables drive activity indicator.

NOTE:

If two (2) drives are installed (with J5 enabled on both drives), both drive activity

indicators will flash simultaneously, 

even

 if only one drive is being accessed.

All manuals and user guides at all-guides.com

Summary of Contents for StorCase Technology Data Express DE100i-A100

Page 1: ...StorCase Technology Data Express DE100i A100 Removable Ultra ATA133 Drive Enclosure User sGuide All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 2: ...ogy Data Express DE100i A100 Removable Ultra ATA133 Drive Enclosure User sGuide Part No D89 0000 0103 C02 October 2005 StorCase Technology Inc 17600 Newhope Street Fountain Valley CA 92708 9885 Phone...

Page 3: ...ase interface cables and other accessories specifically intended for use with the StorCase products identified above are also covered by this 7 year warranty Three Year Warranty The following componen...

Page 4: ...system This warranty covers only repair or replacement of defective StorCase products as described above StorCase is not liable for and does not cover under warranty any costs associated with servici...

Page 5: ...EN 61000 4 4 En 61000 4 8 EN 61000 4 11 EN 60950 CAN CSA C22 2 No 950 95 UL 1950 EN 60950 2000 FCC Part 15 Class B AS NZS 3548 Information Technology Equipment 2000 Company Name Corporate Office Addr...

Page 6: ...he Carrier 7 Drive Activity Indicator Connector J5 7 Installation 8 Installing the Receiving Frame 9 Selecting the Unit ID Number 10 Unit ID Select Switch Settings 12 I O Connector J2 13 APPENDICES 14...

Page 7: ...ons 16 Figure B 1 Attaching the ON OFF Key 17 Figure C 1 Carrying Case 18 Figure C 2 Full Drive Cover 19 Figure C 3 Drive Plug 19 Figure C 4 Solenoid Mechanism 20 List of Tables Table 1 Unit ID Select...

Page 8: ...eller or StorCase at 800 435 0642 to arrange for a Return Material Authorization RMA StorCase cannot ac cept returns which do not display an RMA number on the outside of the package Return the unit wi...

Page 9: ...a Express Dri ve Ca rrie r Dis k Dri ve No t Inc lud ed Pow er Ca ble I O Ca ble Dri ve Mo unt ing Ha rdw are 4e a Phi llips 6 3 2 x 3 1 6 Fla t HD ID Sel ect Ca ble 0151 Ca ble Co ver Pr ovi ded Ca b...

Page 10: ...compatible with earlier technology IDE drives The DE100i A100 allows a drive to be removed and transported to another DE100i A100 equipped computer or expansion chassis and also provides the ability t...

Page 11: ...ical address of the DE100i A100 drive carrier when the carrier is Installed and Locked in the receiving frame or Removed from the receiving frame If the drive carrier is Installed but Not Locked a u w...

Page 12: ...nments Master Slave Selection Jumper J5 Master Drive configuration default Forces master drive configuration on receiving frame Change jumper to set slave drive configuration Refer to Table 1 on page...

Page 13: ...StorCase Technology Inc DE100i A100 User s Guide Rev C02 6 Introduction Figure 5 Receiving Frame Rear Panel All manuals and user guides at all guides com...

Page 14: ...n In most cases the drive will be factory configured as a Master Ultra ATA133 drive using a jumper plug on the drive itself No con figuration changes are required For multiple drive configurations it...

Page 15: ...power cable on the drive carrier circuit board to the drive Carefully insert the drive into the drive carrier at an angle cable end first Make sure none of the cables are pinched Lower the front of t...

Page 16: ...t still be set on the drive itself refer to the drive manufacturer s documentation for further information 0423A Slave Drive Select Master Drive Select Factory Default J5 4 With the drive carrier lock...

Page 17: ...earlier 10 Turn ON power to the computer If the installation has been successful and all the cables have been properly attached the system should boot normally Although the computer may not recognize...

Page 18: ...lists the valid unit ID numbers available for the drive 4 After you have selected an appropriate unit number replace the DE100i A100 carrier in the receiving frame and LOCK IT IN PLACE NOTE The lock o...

Page 19: ...display window Table 1 Unit ID Select Switch Settings NOTE The unit ID number display is for ID display purposes only The master slave setting must still be set on the drive itself refer to the drive...

Page 20: ...O 14 Host Data 13 I O 15 Host Data 1 I O 16 Host Data 14 I O 17 Host Data 0 I O 18 Host Data 15 I O 19 Ground 20 Key NoPin 21 DMARQ O 22 Ground 23 DIOW O 24 Ground 25 DIOR O 26 Ground 27 Reserved 28...

Page 21: ...StorCase Technology Inc DE100i A100 User s Guide Rev C02 14 Appendix A Specifications Dimensions APPENDICES All manuals and user guides at all guides com a l l g u i d e s c o m...

Page 22: ...Storage Ambient Temperature 5 C to 50 C 45 C to 75 C Relative Humidity 1 10 to 80 10 to 90 Altitude 1000 to 50 000 ft 1000 to 50 000 ft 304m to 15240m 304m to 15240m Shock 2 10g 60g 1 Non condensing...

Page 23: ...echnology Inc DE100i A100 User s Guide Rev C02 16 Appendix A Specifications Dimensions Figure A 1 DE100i A100 Physical Dimensions Dimensions are for reference only All manuals and user guides at all g...

Page 24: ...Locate the rectangular shaped key lock mecha nism access hole on the inside of the receiving frame Note that the pawl is in an upright position Insert the key into the lock 2 Rotate the key 90 degree...

Page 25: ...carrier from one site to another in a safe impact and moisture resistant environment Its compact dimensions 7 long x 9 wide x 3 5 high make it easy to carry and to store The foam lining is contoured...

Page 26: ...system or external enclosure bays that are occupied by receiving frames that have no carrier units installed The purpose of the plug is to provide an attractive and functional method of directing pro...

Page 27: ...riod of time can range from 15 40 seconds depending on the type of drive being used e g Barracuda drives require up to 50 seconds Refer to the drive manufacturer s documentation for specific drive inf...

Page 28: ...ne at StorCase Technology is working toward the goal of providing you with the highest quality most cost effective products available on the market and we need your comments to guide our efforts We lo...

Page 29: ...M TO TOP OF PAGE BUSINESS REPLY MAIL POSTAGE WILL BE PAID BY ADDRESSEE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES FIRST CLASS MAIL PERMIT NO 10686 SANTA ANA CA TECHNOLOGY CORPORATION 17600 NE...

Reviews: