background image

Appendix C - Optional Accessories

21

DE75i-A User's Guide - Rev. C01

StorCase Technology, Inc.

Figure  C-1:    Carrying  Case

The optional molded plastic carrying case is designed to transport the DE75i-A carrier from

one location to another in a safe, impact and moisture resistant environment.  Its compact

dimensions, 7” long x 9” wide x 3.5” high, make it easy to carry and to store.  The foam lining

is contoured to fit a single low-profile Data Express carrier (remove the foam piece shown

in the illustration above).  Contact StorCase for further details and ordering information.

Drive
Carrier

DX300-DE-C
Carrying Case

0524

Remove this
Piece of Foam

Appendix C - Optional Accessories

Carrying Case

Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com

All manuals and user guides at all-guides.com

Summary of Contents for StorCase Technology Data Express DE75i-A

Page 1: ...BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspect equipment...

Page 2: ...ow Profile Drive Enclosure User sGuide StorCase Technology Data Express DE75i A Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com All manuals and user guides...

Page 3: ...file Drive Enclosure User s Guide PartNo D89 0000 0058C01 December 2002 StorCase Technology Inc 17580 Newhope Street Fountain Valley CA 92708 9885 Phone 714 438 1850 Fax 714 438 1847 Artisan Technolog...

Page 4: ...ower supply fan and blower components which are covered by the three year warranty described below Three Year Warranty The following StorCase products are covered by this warranty for a period of thre...

Page 5: ...ts identified above and supersedes all other warranties and representations whether oral or written StorCase expressly disclaims all warranties for the identified products which are not stated herein...

Page 6: ...No 950 95 UL 1950 EN 60950 1988 EN 60950 A2 1991 EN 60950 A1 1990 FCC Part 15 Class B AS NZS 3548 Information Technology Equipment 1997 Company Name Corporate Office Address Manufacturing Address Pro...

Page 7: ...guring the Drive Carrier Circuit Board Method 2 6 Installation 11 Installing the Receiving Frame 12 Selecting the Unit ID Number 14 Unit ID Select Switch Settings 15 AT IDE Interface Connector J7 16 A...

Page 8: ...mper JP1 12 Figure 9 Receiving Frame Mounting Holes 13 Figure 10 Unit ID Select Switch Location 14 Figure A 1 DE75i A Physical Dimensions 19 Figure B 1 Attaching the ON OFF Key 20 Figure C 1 Carrying...

Page 9: ...r a Return Material Authorization RMA StorCase cannot accept returns which do not display an RMA number on the outside of the package Return the unit with all the original packing materials Before rem...

Page 10: ...e to Computer 5 Jumper Plugs 6 Drive Lock Keys 7 6 32 x 3 16 Phillips F H Screws Attach Drive and Cable Cover to Carrier 8 Alignment Tool 9 Insert Sheet 10 Drive Cover 4 7 10 5 1 3 8 9 6 2 Data Expres...

Page 11: ...ped computer and also provides the ability to secure sensitive data by removing and storing the carrier drive safely for future use Drive Carrier Receiving Frame 0602 Figure 2 DE75i A Receiving Frame...

Page 12: ...ents unauthorized removal or installation of the carrier For the computer to access data on the DE75i A drive the key must be turned counterclockwise to the locked position The Unit ID Number Indicato...

Page 13: ...tion JP1 ID0 ID1 Master Drive configuration ID0 default Forces master drive configuration on receiving frame Change jumper to set slave drive configuration or remove jumper to use Unit ID Select Switc...

Page 14: ...o additional configuration of the drive carrier circuit board Skip Method 2 below and continue with the Installation section Method 2 Use the hard wire connector J3 on the drive carrier circuit board...

Page 15: ...designed to route the drive s HOST SLV ACT signal drive activity to the activity indicator light on the front panel of the Data Express receiving frame A connection to the J3 Pin 3 on the carrier boa...

Page 16: ...while the connections to J3 Pin 2 should be made with signals from the drive that refer to Slave corresponds to a jumper installed on the carrier L Low corresponds to an installed jumper on the drive...

Page 17: ...nds to an installed jumper on the drive H High corresponds to a removed jumper on the drive If a slave drive is removed Table 3 shows the signal levels on J3 Pin 1 and Pin 2 that will result for diffe...

Page 18: ...D The darkened pin in the figure above is connected to Pin 1 of the provided wire wrap connector DSP Install the jumper in the DSP position as shown in Figure 6 Install the wire wrap connector onto J3...

Page 19: ...e appropriate drive pins and connector J3 on the drive carrier circuit board See Figure 6 for a typical AT IDE drive connection Also refer to the documentation that accompanied the drive for more spec...

Page 20: ...ided Installing the Receiving Frame The drive should be installed into the carrier before installing the receiving frame into the mounting bay of the computer chassis NOTE Use a 2 Phillips screwdriver...

Page 21: ...n 9 Replace any expansion boards that may have been removed earlier Replace the system cover according to the manufacturer s instructions 10 Reconnect any system or peripheral cables removed earlier 1...

Page 22: ...select the ID number of the drive Refer to Figure 10 for the location of the Unit ID Select Switch inside the receiving frame Table 3 lists the valid unit ID numbers that can be used for the drive NOT...

Page 23: ...itch settings have X s and result in a blank display in the receiving frame display window Table 3 Unit ID Select Switch Settings Unit ID Select Position Unit ID Number Display Drive Selection 0 5 4 3...

Page 24: ...Ground 25 HIOR O 26 Ground 27 Reserved 28 Reserved 29 Reserved 30 Ground 31 IRQ 14 I 32 Host IO16 AT I 33 Host ADDR 1 O 34 PDIAG 16 Notes 35 Host ADDR 0 O 36 Host ADDR 2 O 37 Host CS0 O 38 Host CS1 O...

Page 25: ...ions Dimensions 17 DE75i A User s Guide Rev C01 StorCase Technology Inc APPENDICES Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com All manuals and user guid...

Page 26: ...cations Carrier Receiving Frame Height 1 07 27 2mm 1 13 28 7mm 1 Width 4 67 118 6mm 5 75 146 1mm Depth 7 38 187 5mm 8 15 207 0mm Weight 1 1lb 0 50kg 1 1lb 0 50kg 2 Chassis Reliability Maintainability...

Page 27: ...s Guide Rev C01 StorCase Technology Inc Figure A 1 DE75i A Physical Dimensions DImensions are for reference only Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisant...

Page 28: ...nside of the receiving frame Note that the pawl is in an upright position Insert the key into the key lock 2 Rotate the key 90 degrees counterclockwise so that the pawl is visible in the access hole a...

Page 29: ...ong x 9 wide x 3 5 high make it easy to carry and to store The foam lining is contoured to fit a single low profile Data Express carrier remove the foam piece shown in the illustration above Contact S...

Page 30: ...ries StorCase Technology Inc DE75i A User s Guide Rev C01 This Page Left Blank Intentionally Artisan Technology Group Quality Instrumentation Guaranteed 888 88 SOURCE www artisantg com All manuals and...

Page 31: ...l of providing you with the highest quality most cost effective products available on the market and we need your comments to guide our efforts We look forward to hearing from you soon Date Your Name...

Page 32: ...INESS REPLY MAIL POSTAGE WILL BE PAID BY ADDRESSEE NO POSTAGE NECESSARY IF MAILED IN THE UNITED STATES FIRST CLASS MAIL PERMIT NO 10686 SANTA ANA CA TECHNOLOGY CORPORATION 17600 NEWHOPE STREET FOUNTAI...

Page 33: ...r center WE BUY USED EQUIPMENT Sell your excess underutilized and idle used equipment We also offer credit for buy backs and trade ins www artisantg com WeBuyEquipment REMOTE INSPECTION Remotely inspe...

Reviews: