10. Problem check list
Problem
The pilot flame does not light up
The pilot flame goes out
The burner does not light up
Possible cause
Gas valve is turned off
Gas tank empty
Opening blockedt
Air in the system
Loose connections
Dirt at the pilot
Loose connections
Thermocouple is damaged
Leak
Low pressure
Nozzle blocked
Gas valve is turned off
Thermocouple is damaged
The pilot flame burner is bent
The burner is not in the
proper position
Solutions
Turn on the gas valve
Replace the gas cartridge
Clean/replace the opening
Drain the air
Examine all connections
Clean the affected area
Examine all connections
Replace the thermocouple
Examine all connections
Gas cartridge nearly empty, replace it
Clean/replace the nozzle
Turn on the gas valve
Replace the thermocouple
Put the pilot flame burner in the
proper position
Position it properly
11. Sale and spare parts
Service and spare parts:
garbou GmbH
Dornaper Straße 18
D-42327 Wuppertal
kundendienst@garbou.de
Fax: +49 2058 89725-19
Tel.: +49 2058 89725-0
Sales:
BAHAG AG
Gutenbergstr. 21
D-68167 Mannheim
Step 7
Replacing the battery of igniter button
Unscrew the igniter button, load AAA Battery (1,5 V)
like in drawing, tighten the igniter button.
WARNING:
This product contains
small batteries. Swallowed batteries
can cause CHOKING HAZARD.
Seek immediate medical attention if
batteries are swallowed or inhaled.
Keep children away from batteries.
AAA Batterie
(1,5 V)
Ver. 52/2020
GB-BAHAG HS 11kW ANLEITG 29092020 RZ.qxp 29.09.20 14:40 Seite 25
Summary of Contents for 25679582
Page 2: ...2 GB BAHAG HS 11kW ANLEITG 29092020 RZ qxp 29 09 20 14 40 Seite 2...
Page 57: ...57 5 5 1 5 2 5 3 5 4 6 OFF GB BAHAG HS 11kW ANLEITG 29092020 RZ qxp 29 09 20 14 40 Seite 57...
Page 59: ...59 GB BAHAG HS 11kW ANLEITG 29092020 RZ qxp 29 09 20 14 40 Seite 59...
Page 60: ...GB BAHAG HS 11kW ANLEITG 29092020 RZ qxp 29 09 20 14 40 Seite 60...