MT13
5
Main power off alarm
If the main battery is damaged and can not supply power, the built in back up
battery could keep the terminal working, and send a main power failure alarm to the
backend
Displacement alarm
An alarm is generated when the device is set to a displacement of more than 100
meters (message mode prompt), and the alarm information is reported when the
displacement radius exceeds 100 meters when the device is turned off. (Note:
displacement range 100~2000m)
Low Voltage Alarm
When the battery voltage on the vehicle is too low (0-11V or 19-22V), the vehicle
terminal reports a low voltage alarm to the backend
Vibration Alarm
The device activates the vibration alarm function. After the device is turned off for
more than 10 minutes (the fortification range: 1~20 minutes), the device generates
vibration and the ACC is not connected within 3 minutes (delay range: 1~10
minutes), and the device will report the vibration alarm information.
【
Intelligent function
】
Intelligent Power Save
The terminal has a built-in high-sensitivity G-sensor accelerometer that monitors the
vehicle for motion in real time. When no motion is detected for a long time, the
terminal automatically enters the power saving state, turns off the GPS/BD module,
GPS Talks