13
4.2.2 Set the return interval
Instruction format: HC, T1, T2, T3#
Instructions:
T1: Start the return interval, the value range is 5-1800 seconds, the default is 30
seconds
T2: Turn off the return interval, the value range is 5-1800 seconds, the default is 120
seconds
T3: Sleep return interval, the value range is 15-21600 seconds, the default is 180
seconds
Example: HC,60,180,300# Set T1/T2/T3 to 60 seconds, 180 seconds, 300 seconds
respectively
Use note:
It is strictly forbidden to use the equipment in violation of the operating instructions,
disassemble it without permission, collide, charge, soak in water, exceed 80°C,
man-made failure, force majeure damage, etc., otherwise it may cause short circuit,
insufficient working time, battery deformation, leakage, explosion, etc. No warranty
or compensation will be made for joint losses.
4.3 Installation location
MT36 is designed to meet the IP68 protection standard and can be installed and
fixed in exposed environments. Normally, it can be fixed at the position identified in
the figure below, and the equipment line is routed along the original car harness.