background image

BarFly  400D

Operation Manual

 

Part No. 3100069 Rev A                                                                                         06-22-2013

®

Summary of Contents for BarFly 400D

Page 1: ...BarFly 400D Operation Manual Part No 3100069 Rev A 06 22 2013 ...

Page 2: ... K32 55W Kino KF32 Quad 55Q K55 55W Kino KF55 Quad BAR 400D 120U BarFly 400D Univ 120U BAR 400D 230U BarFly 400D Univ 230U GFR B4 BarFly 400 Gel Frame Included LVR B490 BarFly 400 Louver 90 Included MTP BL41 Kino 41L Mount w Baby Receiver 16mm ...

Page 3: ... 400D Kit Univ 120U 1 Unit KIT B41D 230U BarFly 400D Kit Univ 230U 1 Unit Kit Contents 1 BarFly 400D 1 Mount 1 Medium Duty Stand 30 1 Lamp Case 1 Travel Case Dimensions Weight 31 5 x 9 x 22 32 lb 80 x 23 x 56cm 14 5kg BarFly 400D Kit 1 Unit ...

Page 4: ... with lamp holder Gently lay lamp down into fixture Caution If there is any resistance realign the angle of the lamp and try again Apply adhesive transfer tape to the gel frame Press lamp securely into lamp clip Lay the adhesive side on the gel and trim off excess gel with a matte knife ...

Page 5: ... accessory locking tab counter clockwise to open accessory holder Gel frame fits into lower accessory channel The louver slides into the upper accessory channel Rotate locking tab clockwise to lock accessories in place both ends of fixture ...

Page 6: ...re loop provides an attachment point for a safety chain if fixture is hung from a grid A 180 turn loosens the orientation of the mount A right turn tightens the mount The tension on the lock lever may be adjusted by pulling the handle away from the mount This disengages the handle from the screw mechanism and allows the lever to be reori ented 6 To remove the plate pull up on the locking pin and r...

Page 7: ...ver 16mm MTP LBS Kino 41 Lollipop w Baby Receiver Short 16mm Correct Lamp Orientation Do not operate fixture in a base down position Base down position may result in increased Kelvin and increased green spike For stable color rendering use lamps in either the base up position or the horizontal position 7 ...

Page 8: ...be on If it is not Voltage is not present Check your power feed The onboard dimmer should be full up turned completely clockwise All lamp switches should be in the ON position Check lamp contact Once everything has been checked re strike Warning To Ensure Proper Operation ALWAYS TURN OFF THE FIXTURE BEFORE connecting or disconnecting lamps After the lamps are properly installed the in line switch ...

Page 9: ...e will shift marginally if kept to within one f stop Dimming beyond one f stop may result in a reduction of color temperature as well as a noticeable shift to magenta Manual Dimming Control The BarFly 400D features a built in dimmer control For full light output turn dimmer fully clockwise An input jack for an optional Remote Dimmer DIM 5 is located next to the manual dimming knob Note The ballast...

Page 10: ...unt w 3 8 Pin 10mm MTP L Kino 41 Lollipop w 3 8 Pin 10mm MTP LB Kino 41 Lollipop w Baby Receiver 16mm MTP LBS Kino 41 Lollipop w Baby Receiver Short 16mm LVR B460 BarFly 400 Louver Honeycomb 60 LVR B445 BarFly 400 Louver Honeycomb 45 10 GFR B4 BarFly 400 Gel Frame Included STD M30 Medium Duty Stand 3 Rise 30 ...

Page 11: ...ad 55Q K5X 55W Kino 550 Green Quad Cases Part Number Description Dimensions Weight Empty Holds KAS B4 C BarFly 400D Travel Case 1 Unit 31 5 x 9 x 22 80 x 23 x 56cm 15 lb 7kg BarFly 400D Kit Items KAS QL6 6 Lamp Carry Case Quad 16 x 7 5 x 4 5 40 6 x 19 1 x 11 4cm 1 lb 0 5kg Quad Lamps 6 KAS B4 C KAS QL6 ...

Page 12: ...ming Range 100 5 Weight w lamps 12 lb 5 5kg Dimensions 17 x 16 x 4 5 43 x 41 x 11 5cm Lamp Type F55 QFL Fixture Specifications For latest Warranty information and Certifications see Kino Flo website at www kinoflo com Environmental Disposal of Old Electrical Electronic Equipment This symbol on the product or on its packaging indicates that this product shall not be treated as household waste This ...

Reviews: