DCP 30 LX / DCP 30 SX
Transport and Installation
Issue: 11/2009
15
2 .4
Connecting Panel (Inputs)
1
2
3a
4
6
5
3b
2 .4 .1 Inputs for D-Cinema “VIDEO IN”
BNC connector “SMPTE 292 IN” (A & B):
Inputs for D-Cinema server with HD /SDI out (single or dual link)
DVI IN connectors (A & B):
Inputs for D-Cinema server with DVI out
(single or dual link)
2 .4 .2 Inputs / Outputs “CONTROL”
3a
Serial Connector “SERIAL NETWORK RS232/422” (IN & OUT)
Serial interface, e. g. for DCP Communicator control software
Selection of RS-232 or RS-422 is configured by service via Communicator.
3b
Serial Connectors “SERIAL NETWORK RS232/422” (IN & OUT)
Serial interfaces, e. g. for connecting several serial device. Each of the devices
needs a determined address (configuration via DCP Communicator).
GENERAL PURPOSE IN/OUT
Connection to GPI/O connecting area (please, do not disconnect)
not used
Network Connectors “10/100 BASE T” (Port 1 & 2)
• Connection to external PC with Communicator software, Touch panel PC, etc.
• Connection to D-Cinema server for features like CineCanvas (subtitle), CineLink2
(coding), meta data exchange and automation