KINOVA
®
Gen3 Ultra lightweight robot
User Guide
13
Table 2: General
Do not connect the USB ports on the base to one another.
It is recommended that surge protection be used to protect the robot against external surges on
the main AC line which might be caused by lightning or other abnormal conditions.
The base must be mounted as specified in the installation section, with particular attention to the
bolt pattern, strength requirements and any table or tripod-specific mounting.
The end effector must be mounted as specified in the installation section (including bolt pattern,
power requirements, etc.).
Table 3: Maintenance
Immediately following exposure to saline air conditions, contact Kinova support to schedule
maintenance by authorized Kinova technician.
The controller mating interface must be kept free of dust and moisture to protect the electrical
contacts. Wipe down the surface with a soft dry cloth to keep the surface of the interface clean.
The robot should not be used without the provided emergency stop connected.
Do not operate the robot when the relative humidity exceeds the maximum specified limit. In such a
case, put down any object in the gripper, bring the robot to a resting position and wait until the humidity
decreases to an allowable value.
The robot is not certified for use in applications in sterile environments (e.g. food production,
pharmaceuticals, medical, surgical).
Do not use the robot in heavy rain. If this happens, contact Kinova support to schedule
maintenance by an authorized Kinova technician.
Do not power on the product if any external damage to the Vision module is apparent.
Do not
attempt to open the Vision module.
The Vision module depth sensor includes a Class 1 infrared laser. To avoid eyesight injury from
wide angle infrared laser light, do not view the front-facing surface of the Vision module through
magnifying optical elements.