KINOVA
®
Gen3 Ultra lightweight robot
User Guide
23
Figure 4: Base mounting holes pattern
Robot power adapter and E-stop
This section describes the power adapter and E-stop.
The power adapter allows power to be supplied to the robot using a wall outlet as a source. The
cable from the power adapter connects to the power connector on the base controller using a
Lumberg 0322 08 connector.
The cable from the power adapter to the robot includes an integrated push-button E-stop
connected in series. The E-stop allows users to shut down the robot quickly in case of an
emergency.
To engage the E-stop, press down on the red button on top of the E-stop. This will cut the power
to the robot, causing it to shut it down.
When the power is cut, the robot will descend. There are mechanisms within the large
actuators to slow the fall of the arm for safety purposes. However, it is recommended that if
possible, users cradle the robot as it falls.
To disengage the E-stop, rotate the button clockwise until it pops up.
Powering on the robot
This section describes how to connect the robot to an electrical power source.
The robot is powered by a 24V power supply (P/N DTM300PW240D2).