background image

 

ENGLISH 

Intended

 

Use

 

The

 

Kinsa

 

Smart

 

Ear

 

Thermometer

 

is

 

intended

 

to

 

measure

 

the

 

human

 

body

 

temperature

 

in

 

the

 

ear.

 

This

 

device

 

is

 

reusable

 

for

 

clinical

 

or

 

home

 

use

 

on

 

both

 

adults

 

and

 

children.

 

 

Warnings

 

And

 

Precautions

 

 

This

 

thermometer

 

functions

 

with

 

most

 

Apple

 

and

 

Android

 

mobile

 

devices.

 

Please

 

see

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 


kinsahealth.com/phones

 

for

 

the

 

full

 

list

 

of

 

supported

 

devices.

 

Clean

 

the

 

probe

 

before

 

and

 

after

 

use.

 

Never

 

use

 

the

 

thermometer

 

for

 

purposes

 

other

 

than

 

body

 

temperature

 

measurement.

 

Please

 

follow

 

the

 

safety

 

precautions

 

when

 

using

 

on

 

children.

 

The

 

operating

 

ambient

 

temperature

 

range

 

for

 

this

 

thermometer

 

is

 

59°

 

-

 

104

 

°F

 

(15-

 

40

 

°C).

 

Do

 

not

 

expose

 

the

 

thermometer

 

to

 

temperature

 

extremes:

 

(below

 

-13

 

°F

 

/

 

-25

 

°C

 

or

 

over

 

131

 

°F

 

/

 

55

 

°C)

 

or

 

excessive

 

humidity

 

(>95%

 

RH).

 

Use

 

of

 

this

 

thermometer

 

is

 

not

 

intended

 

as

 

a

 

substitute

 

for

 

consultation

 

with

 

your

 

physician.

 

High,

 

prolonged

 

fever

 

requires

 

medical

 

attention.

 

Be

 

sure

 

to

 

contact

 

your

 

physician.

 

The

 

thermometer

 

is

 

water

 

resistant,

 

not

 

waterproof.

 

Never

 

dip

 

the

 

thermometer

 

into

 

water

 

or

 

other

 

liquids.

 

Do

 

not

 

boil

 

the

 

probe.

 

For

 

cleaning

 

and

 

disinfecting,

 

please

 

see

 

Cleaning

 

and

 

Storage.

 

Keep

 

out

 

of

 

reach

 

of

 

unattended

 

children.

 

Do

 

not

 

allow

 

children

 

to

 

walk

 

or

 

run

 

while

 

taking

 

a

 

temperature.

 

Kinsa

 

recommends

 

using

 

a

 

password

 

on

 

your

 

smartphone

 

to

 

protect

 

your

 

information. 

The patient is an intended operator. 
Do not perform maintenance and checks during operation. 
The ear thermometer with installed probe cover is considered an applied part and has 
been tested and evaluated accordingly.

Features

 

of

 

your

 

Kinsa

 

Smart

 

Ear

 

Thermometer

 

 

Fast

 

1

 

second

 

reading.

 

 

Meets

 

ASTM

 

&

 

ISO

 

standards

 

for

 

professional

 

accuracy.

 

 

Gentle

 

and

 

easy

 

to

 

use

 

in

 

the

 

ear.

 

 

No

 

probe

 

covers

 

needed.

 

 

Conveniently

 

displays

 

in

 

°F

 

or

 

°C.

 

 

Water

 

resistant,

 

for

 

safe

 

cleaning.

 

 

Use

 

with

 

or

 

without

 

your

 

mobile

 

device.

 

Connects

 

via

 

Bluetooth

 

Low

 

Energy.

 

 

Additional

 

Smart

 

functionality

 

available

 

through

 

Kinsa

 

app.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 
 

3

 

Summary of Contents for KET-005

Page 1: ...ions carefully to ensure accurate temperatures and safe operation Your Kinsa Smart Ear Thermometer is optimized for use with the free Kinsa app but can be used alone as well For the full experience including features such as symptom tracking and fever guidance download the app on the App Store or Google Play store and connect your thermometer to your mobile device For the full list of supported de...

Page 2: ...Product Description C B F A D E G A B C D E F G Power Start button Probe Probe tip Display Battery door Protectivecap Kinsa mobile app 2 ...

Page 3: ...longed fever requires medical attention Be sure to contact your physician The thermometer is water resistant not waterproof Never dip the thermometer into water or other liquids Do not boil the probe For cleaning and disinfecting please see Cleaning and Storage Keep out of reach of unattended children Do not allow children to walk or run while taking a temperature Kinsa recommends using a password...

Page 4: ... illness and you should consult your physician The ear thermometer may be used by children only under adult supervision Measurement is usually possible over the age of 6 months In infants under 6 months the ear canal is still very narrow so the temperature of the eardrum often cannot be recorded and the result displayed is often too low Why Measure in the Ear Ear temperatures accurately reflect co...

Page 5: ...ome screen or in your Apps folder depending on type of mobile device Turn the thermometer on and follow the prompts to install Your thermometer is now successfully connected to your mobile device For future temperature readings open the Kinsa app to automatically sync readings to your mobile device and assign to individual family members add notes or symptoms medications and see guidance To Set Up...

Page 6: ... often too low The measurement must not be taken in an ear affected by inflammatory diseases e g discharging pus or secretion after possible ear injuries e g eardrum damage or in the healing period after operative procedures In all of these cases please consult your doctor Use of the thermometer on different persons can be inappropriate in the event of certain acute infectious diseases because of ...

Page 7: ...the head Once in position push and release the Power Start button A beep will indicate when the temperature measurement is successfully completed Temperature readings typically take 1 second The temperature reading will be shown on the illuminated display A smiling face icon indicates that the temperature is normal while a neutral or frowning face indicates a mild or high fever respectively The th...

Page 8: ...ontact Kinsa Customer Support APP ERR Connect to Kinsa app Please refer to the set up process The operating Operate the thermometer only temperature is not between the specified temperature in the range 15 C 40 C ranges Kinsa App Set Up Process Download the Kinsa app from the App Store or Google Play The app can also be downloaded by going directly to kinsahealth com download Please see kinsahealt...

Page 9: ... is low To replace the batteries E Open the back battery coverE by pressing on the Kinsalogo and applying downward pressure to slide it off Remove the old batteries and replace with new ones Make sure the the batteries are in the correct polarity direction Close the battery cover To protect the environment dispose of the product and empty batteries at your retail store or at appropriate collection...

Page 10: ...OR 95 0 F 107 6 F 36 C 39 C Outside this range Typical Service Life 3 years 0 4 F 0 6 F 0 2 C 0 3 C Temperature of Storage and Transporation Range Humidity of Storage and Transporation Range 4 F to 122 F 20 C to 50 C 0 95 RH non condensing Batterytype Batterylife Bluetooth Operating Transport Storage Atmospheric Pressure Two AAAbatteries Approx 2 years Bluetooth 5 700hPa 1060hPa Guarantee of Quali...

Page 11: ...tes uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and...

Page 12: ...miditylimitation Dust and water rating Manufacturer batch code Catalogue number Non sterile FCC ID 2AFEOSE3 Product contains no latex Type BF applied part Do not use if product is broken damaged or open L 10252 RevA Copyright 2017 Kinsa Inc For patents kinsahealth com patents 12 ...

Page 13: ...ns CISPR 11 Group 1 The Kinsa Smart Ear Thermometer uses RF energy only for its internal function Therefore its RF emissions are very low and are not likely to cause any interference in nearby electronic equipment RF emissions CISPR 11 Class B The Kinsa Smart Ear Thermometer is suitable for use in all establishments including domestic establishments and those directly connected to the public low v...

Page 14: ...0 5kV 1kV line s to line s 0 5kV 1kV 2kV line s to earth Not applicable Not applicable Mains power quality should be that of a typical home healthcare environment Voltage Dips short interruptions and voltage variations on power supply input lines IEC 61000 4 11 Voltage dips 0 UT 0 5 cycle 0 UT 1 cycle 70 UT 25 30 cycles Voltage interruptions 0 UT 250 300 cycle Voltagedips Not applicable Not applic...

Page 15: ...MHz 2 7 GHz 80 AM at 1 kHz Portable and mobile RF communications equipment should be used no closer to any part of the Kinsa Smart Ear Thermometer including cables than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter Recommended separation distance d 1 2 d 1 2 80MHz to 800 MHz d 2 3 800MHz to 2 7 GHz Where P is the maximum output powe...

Page 16: ...ted maximum output power of transmitter W Separation distance according to frequency of transmitter m 150 kHz to 80 MHz d 1 2 80 MHz to 800 MHz d 1 2 800 MHz to 2 7 GHz d 2 3 0 01 N A 0 12 0 23 0 1 N A 0 38 0 73 1 N A 1 2 2 3 10 N A 3 8 7 3 100 N A 12 23 For transmitters rated at a maximum output power not listed above the recommended separation distance d in meters m can be estimated using the eq...

Page 17: ...5 780 810 800 960 GSM 800 900 TETRA 800 iDEN 820 CDMA 850 LTE Band 5 Pulse modulation b 18 Hz 2 0 3 28 28 870 930 1 720 1 700 1 990 GSM 1800 CDMA 1900 GSM 1900 DECT LTE Band 1 3 4 25 UMTS Pulse modulation b 217 Hz 2 0 3 28 28 1 845 1 970 2 450 2 400 2 570 Bluetooth WLAN 802 11 b g n RFID 2450 LTE Band 7 Pulse modulation b 217 Hz 2 0 3 28 28 5 240 5 100 5 800 WLAN 802 11 a n Pulse modulation b 217 ...

Reviews: