Installation and initial operation
36
01.04.2020
aPWM 1
Analogue pulse width modulation, output 1
aPWM 1A
Analogue pulse width modulation, output 1, direction A
aPWM 1B
Analogue pulse width modulation, output 1, direction B
aPWM 2
Analogue pulse width modulation, output 2
aPWM 2A
Analogue pulse width modulation, output 2, direction A
aPWM 2B
Analogue pulse width modulation, output 2, direction B
AUX 1
Auxiliary circuit 1
AUX 1A
Auxiliary circuit 1, direction A
AUX 1B
Auxiliary circuit 1, direction B
AUX 2
Auxiliary circuit 2
AUX 2A
Auxiliary circuit 2, direction A
AUX 2B
Auxiliary circuit 2, direction B
Extra 1
Extra function 1
Extra 1A
Extra function 1, direction A
Extra 1B
Extra function 1, direction B
Extra 2
Extra function 2
Extra 2A
Extra function 2, direction A
Extra 2B
Extra function 2, direction B
QC
Quick coupler
Steering or caterpillar control active
Steering not permitted
Forwards/backwards in caterpillar control mode
4.2.3.
Starting commissioning mode
To carry out the commissioning, the functions for setting the tiltrotator and the
quick coupler must first be enabled.
Prerequisite:
•
The excavator engine is switched off.
1. Switch on the excavator ignition to switch on the power supply.
DANGER
Fatal hazard due to unexpected movements of the excavator arm!
•
Make sure that the engine remains switched off.
2. Wait until the terminal has booted.