KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
45
“Minimum with hysteresis”
if the measured value of the logger goes below the
lower limit, the alarm/actuator is activated. The alarm/actuator will not be
deactivated until the measured value exceeds the upper limit.
“Maximum with hysteresis”
if the measured value of the logger channel
exceeds the upper limit, the alarm/actuator is activated. The alarm/actuator will
not be deactivated until the measured value goes below the lower limit.
“Out of range”
if the measured value of the logger channel is out of the range
defined by the levels, the alarm/actuator is activated.
“Within the range”
if the measured value of the logger channel is within the
range defined by the levels, the alarm/actuator is activated.
In addition to the above described, any of the six outputs can be activated at certain
hours, individually selectable by the user in Atlas.
4.6
Atlas desktop software
Atlas is our latest desktop software to manage and connect with the data loggers from
Kintech Engineering. The updated workspace in Atlas lets track the entire fleet of data
loggers and automate all the “daunting” tasks so it can be focused on key factors that
directly influence the overall data quality of the measurement campaign.
4.6.1
Atlas Free
Atlas Free has the same functionalities that EOL Manager has plus the availability of
managing Orbit 360 data loggers too and some new features such as the optimized
connectivity for sites with unreliable GSM connection (smart connection), enhanced
sensor status flags with built-in logic, improved real-time connection windows and a
new calendar showing daily data availability.
4.6.2
Atlas Professional
Atlas Professional includes more advanced new features such as a new 3rd level
password for 3rd party decoding, a complete timeline of the site history displaying all