ORBIT 360 | USER GUIDE
52
When the software is decoding the raw data stored from the logger, depending on the
type of instrument set up in the software site settings, it will convert from the total
number of pulses to hertz by dividing it by the storage interval duration. For types of
instruments like precipitation sensors or water counters, the software will use the total
number of pulses rather than frequency.
When the sensor type configured on the logger settings is an associated digital serial
input data, the origin of the data is not the pulse count from its associated input channel
terminal but the corresponding field from its associated digital serial input instrument
telegram.
The number of physical channels available on each logger depends on the commercial
model chosen. The following table is a summary of the frequency channel
characteristics.