KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
59
The internal batteries are only intended for backup and emergency mode operation in
case the external power supply stops working or it is stolen. An external power supply is
always required for normal operation.
Remark:
The only way to turn on the logger once it has been powered off is by means of
an external power supply. It cannot be switched on through the internal
backup batteries.
To turn off Orbit 360 data loggers featuring internal batteries the user must:
1
st
) Unplug the 3-terminal orange power plug to disconnect the external power
supply.
2
nd
) Follow the instructions on the display and press UP + SET + DOWN to also
disconnect the internal power supply.
5.7.3
Physical characteristics
Property / Description
Specification
Comments
Dimensions
263x180x88
mm
Weight
1.8
kg
Display
128x64 pixel resolution
LCD
Keypad
5
buttons
LEDs
3
Modem, GPS, CPU