KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
111
In less than a minute you will receive a SMS back with the site information. A typical use
of SMS is the maintenance staff wanting to know if wind conditions are good enough to
work in the wind farm. Another typical use is to know when the logger is powered on in
the system commissioning or when the system recovers the GSM signal after long time
without it.
The SMS report contains information like site number, date and time, battery, last ten
minute averages of wind speeds in m/s, wind direction in degrees and other analog
inputs in the configured physical unit for each input.
Example:
Sit 990003 06:23 15/07/2010 Bat=13.6V Status: OK
m/s: 9.5 9.4 9.0 9.5
Dir:264 307 Analog:18C 907mbar -0.3m/s 63%
9.1.4
The Orbit 360 data logger can be set up to send data via email. For the logger to be able
to send emails, you have to configure the following parameters:
Email frequency
Email frequency can be set to a range from one to seven days.
Time
The time at which emails will be sent can be configured from 0h to 23h (UTC).
Sender email address
The sender email address is typically the SMTP user name as a full email address and
is the unique email address assigned to the logger. This email address will appear in
the “From” field of the emails the Orbit 360 will send.
Recipient email address 1
First email address to which the logger will send the data files.