KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
53
Property / Description
Value
Comments
Number of physical channels
10
Basic Plus
10
Premium
Number of virtual channels
(RS485 sensors)
0
Basic Plus
6
Premium
Resolution
16
Bits
<0.01 m/s
wind speed (avg.)
0.05 m/s
Gust
0.01 m/s
Std. deviation
Voltage Threshold
1.5V
Default (Hertz’s)
*auto
80mV to 2.5V
Input Resistance
220
kΩ
Frequency range
0 to 2
kHz
*The voltage threshold is automatically set according to the signal characteristics of the
configured sensor.
5.4.2
Analog channels
The Orbit 360 data logger reads the analog input channels through its 12-bit analog to
digital converters. In turn, this provides a 0.025% resolution throughout its 0 to 5V range.