KINTECH ENGINEERING
ORBIT 360 | USER GUIDE
64
Remark:
The data logger GND terminal (to which all the sensors shields must have been
previously connected) should always be connected to a separate ground rod
and NOT to the lightning rods (Fig. 14).
Copper ground wire should be as short as possible and should be installed as straight
as possible avoiding loops or angles.
Fig. 14.
How to ground the logger
6.4
Antennas
There are two antennas that come with the Orbit 360 data logger: a GSM antenna (see
Fig. 15) and a GPS antenna (Fig. 16). Both of them are strongly magnetized at theis base
for ease of installation.