M0275-01
Model 3700
5-40
Rev. 10/18
TM
Lubrication and Maintenance
ELECTRICAL CONTROL CONSOLE SCHEMATIC
NOTE:
1. Operating row marker or point row switch in either direction lights panel light.
2. Point row clutch switch operates independently from rest of control box.
3. Power to row marker switch is fed through auxiliary switch and two transport function switches.
Operating any switch in lower row disables row marker function and turns off panel light. (If point row
clutch switch is “OFF”.)
4. See page 6-43 for two-speed point row clutch electrical control console and wiring harness schematics.
MAIN
FUSE
15A
USE 10 AMP
DELAY
ACTION
ONLY
POINT ROW
OFF
LEFT
ON
OFF
AUXILIARY
ROTATE
TONGUE
OFF
RIGHT
LEFT
MARKER
OFF
WING LOCK
RAISE
MARKERS WILL NOT FUNCTION WITH AUXILIARY SWITCH ON
RIGHT
fi
Pin “C” Black/Red (Ground)
Pin “T” Black (Ground)
Black (-12 VDC)
Red (+ 12 VDC)
Pin “B” Blue/Red (Rotate)
Pin “W” Orange/Black (Auxiliary)
Pin “R” Brown (Left point row clutch)
Pin “G” Orange (Right point row clutch)
Pin “H” Blue (Left marker)
Pin “O” Red (Right marker)
Main fuse (15A)
Delay Action Fuse (10A Slow-Blow)
Point row clutch switch
Auxiliary switch
Rotate/Tongue switch
Indicator light
Marker switch
Raise/Wing Lock switch
Pin “F” Yellow/Red (Not used)
Pin “V” Blue/Black (Raise)
Pin “A” Orange/Red (Tongue)
Disconnect control console
from tractor battery before
doing any electrical work
or shorting will damage
equipment. Keep wiring
harnesses away from high
temperature areas or sharp
edges. DO NOT route wiring
harnesses along battery
cables. Use cable ties to
keep wire harness away
from moving parts on
tractor and planter. Ground
connections to tractor frame
must be clean to provide
good electrical contact.
NOTICE