6.1 SOLYS Gear Drive specifications
Pointing accuracy
Active tracking
Performance
SOLYS Gear Drive
Comments
Torque
Payload
Power consumption during Sun cycle
< 0.02 °
> 40 Nm
At 2.5 °/s angular velocity
Torque at sun tracking speed
> 60 Nm
At 0.004 °/s angular velocity
80 kg
Angular velocity
2.5 °/s
Angular acceleration
3.6 °/s2
Rotation
110 ° zenith
540 ° azimuth
Protection against over rotation/damage
Physical limit stops
Balanced
25 W maximum
175 W maximum
DC power
AC Power with heater operating
Power consumption after Sun cycle
13 W maximum
163 W maximum
DC power
AC Power with heater operating
Maximum operating temperature
+55 °C
+60 °C
At 1000 W/m2 without sun shield
At 1000 W/m2 with sun shield
Minimum operating temperature
-50 °C
-50 °C
AC power without cold cover, wind speed ≤ 1.5 m/s
AC power with cold cover, wind speed ≤ 20 m/s
For standard sun tracker
For SOLYS Tripod Floor Stand
For Heavy Duty Tripod Floor Stand
Storage temperature range
-50 °C to +60 °C
Weight
26 kg
5 kg
10.5 kg
Includes standard pyrheliometer mounting
Dimensions (w x d x h)
50 x 34 x 38 cm
(excluding Tripod Floor Stand)
Relative to zenith shaft
Bubble level accuracy
< 0.1 °
Environmental protection
Suitable for all-weather outdoor use
Compliance to international standards
CE compliance
Materials
IP 65
Yes
RoHS compliance
Yes
Suitable for coastal use and areas with pollution
Transmission
No adjustment or maintenance needed (for 10 years)
Features
Power connections
Gear drives
Socket for AC power, DC power
Plugs for AC and DC supplied
Ethernet interface
RJ-45
DHCP client / Zeroconf
Manual network configuration
ICMP type 8 and 17
mDNS, UDP port 5353
Web interface, TCP port 80
NTP service , UDP port 123
Track commands, TCP port 15000
Status info, TCP port 15001
RS-485 interface
4 wire isolated, EMI protected
Binder 8 pin connector
The interface supports: status info, recovery info and interface configuration
GPS for location and time/date
Standard
Antenna on top of housing
Pyrheliometer mounting
One side plate and mounting kit as standard
For all Kipp & Zonen pyrheliometers
Mounting base
LED Indicators
Optional Tripod Floor Stand
Power, internal temperature and status
Includes adjustable feet for leveling
Multi-color to indicate various modes
Sun sensor kit
For active sun tracking
Plug in unit with alignment adjustment
Supply voltage
Auto switching, AC when both connected
For world-wide use
Operating Conditions and Dimensions
18 to 30 VDC (nominal 24 VDC)
100 to 240 VAC, 50/60 Hz
6. Specifications
Installation
GPS acquires location and time / date
Customer operation
Comments
Functional self test
Plug-and-play, no computer required
Standard
Multi-color LED status indicator
Cable length test at power on
Test / diagnostic facility
Standard
Via Ethernet port
Sun tracking mode
Standard
Michalsky algorithm (1988)
Firmware update possible
Flash memory
Maintenance
No scheduled maintenance required
Annual inspection recommended
Via Ethernet port
Automatic restart after power
interruption
Yes
Computer system requirements
Ethernet connection, web browser, mDNS
Not needed for installation, provides status status and communication parameters
81
Summary of Contents for SOLYS Gear Drive
Page 1: ...SOLYS2 Sun Tracker SOLYS Gear Drive Sun Tracker Instruction Manual...
Page 2: ...2...
Page 4: ...4...
Page 6: ...6...
Page 10: ...10...
Page 39: ...Figure 3 13 Adjustment of the sun sensor 21 0 5 mm 3x 39...
Page 61: ...6 Insert the Ethernet cable Contacts on this side 61...
Page 78: ...78...
Page 80: ...80...
Page 86: ...86...
Page 88: ...88...
Page 112: ......