5. Commissioning, Operation
The following malfunctions could occur:
Fault:
Termination of radio communication
Cause:
Connected devices out of radio range
Performance:
“Radio Link” LED goes out 2 seconds after the last communication.
The relays drop out and the basic state „Normally Closed“ or „Normally Open“,
depending on the circuitry, is established.
This response can be adapted on request.
Countermeasure:
Move the device within reach
To reconnect, the device must not be in idle mode.
Fault:
Interruption of the power supply
Cause:
Intentional or unintentional disconnection of the power supply.
Performance:
“Power” LED is not lit
The relays drop out and the basic state, depending on the circuitry, is established.
The linked KIPP devices go into idle mode after 30 seconds.
Countermeasure:
Restore the power supply
Reset connected KIPP devices from idle to operating mode.
5.4.2 Malfunctions
6. Care and Maintenance
The Gateway is maintenance-free.
The Gateway can be cleaned with a dry cloth.
6.1 Maintenance
6.2 Cleaning