FP520 Service Manual
Page 28 of 64
Chapter 9 KBC-51 Charger
9.1 The Operational Conditions and Basic Specification of Charger
a) Battery Specification
:
Li-ion
(
2*3.7V
),
Ni-MH (6*1.2V)
,
battery capacity (1~2.4AH).
b)Power Adaptor Specification: DC 11V~16V
,
500~1500mA power adaptor
,
standard voltage is 12V.
c) No-load Input Current
:
≤ 15mA
d) Precharged Current
:
75 mA±10 mA
e) Precharged Time Limit
:
15Min
f) Constant Current Charging Current
:
400 mA±40 mA
g) Maximum Li-ion Charging Voltage
:
8.32~8.42V
;
Maximum Ni-MH Charging Voltage: 9.6±0.1V
9.2 Function Introduction
1. This charger is intelligent with fast charging, reliability, safety and high charging saturation.
2. Status Indication: The indicator flashes red for precharging and lights red for charging; it lights green for
full charging, no battery and battery protection; it flashes yellow for battery output short circuit.
3. The external port identifies the lithium battery and Ni-MH battery.
4. Battery Short Circuit Protection: When there is a short circuit in the negative and positive pole of the charger,
the indicator flashes yellow and the charging current will be cut off. The charging will continue automatically after
troubleshooting.
5. The full battery is recharged for identification: When the full NI-MH battery is recharged, it will continue the
charging. The charger according the normal
–ΔV to identify if the battery is full charged. When the full Li battery
is recharged, if the voltage is higher than 8.25V, the charging stops, and if it is lower than 8.25V, the charging
continues.
6. Temperature Protection: When the Li-ion battery is charging, the charging stops with the yellow light on if the
temperature is higher than 55 degrees. The charging is restarted when the temperature is down to 45 degrees.
When the Ni-MH battery is charging, the charging stops with the yellow light on if the temperature is higher than
60 degrees. The charging is restarted when the temperature is down to 50 degrees.
7. Put the radio on the charger when it is on standby mode, and the charging automatically begins when the
battery voltage is lower than 8.2 V.
8. The yellow light indicates the charger automatic protection. The charging is restarted after the
troubleshooting.
LED lights red: Charging
LED lights green: Full battery
LED lights yellow: Abnormal charging
Summary of Contents for FP520
Page 1: ... 键入文档副标题 gh 选取日期 在此处键入文档的摘要 摘要通常是对文档内容的简短总结 在此处键入文档的摘要 摘要 通常是对文档内容的简短总结 ...
Page 44: ...FP520 Service Manual Page 43 of 64 Figure 1 FP520 01 Mainboard Schematic Diagram 136 174MHz ...
Page 45: ...FP520 Service Manual Page 44 of 64 ...
Page 46: ...FP520 Service Manual Page 45 of 64 ...
Page 47: ...FP520 Service Manual Page 46 of 64 ...
Page 48: ...FP520 Service Manual Page 47 of 64 ...
Page 49: ...FP520 Service Manual Page 48 of 64 ...
Page 50: ...FP520 Service Manual Page 49 of 64 ...
Page 51: ...FP520 Service Manual Page 50 of 64 ...
Page 54: ...FP520 Service Manual Page 53 of 64 Figure 4 FP520 02 Mainboard Schematic Diagram 400 470MHz ...
Page 55: ...FP520 Service Manual Page 54 of 64 ...
Page 56: ...FP520 Service Manual Page 55 of 64 ...
Page 57: ...FP520 Service Manual Page 56 of 64 ...
Page 58: ...FP520 Service Manual Page 57 of 64 ...
Page 59: ...FP520 Service Manual Page 58 of 64 ...
Page 60: ...FP520 Service Manual Page 59 of 64 ...
Page 61: ...FP520 Service Manual Page 60 of 64 ...
Page 64: ...FP520 Service Manual Page 63 of 64 Figure 7 KBC 51 7 4V Electrical Schematic Diagram ...