If your dealer have programmed QT/DQT in your transceiver,
when you select the channel with this function, you can only
hear the calling with the same QT/DQT tone.
This function can make you filter the unnecessary calling, even
as if you use the special channel when the QT/DQT enabled,
the other party with the same QT/DQT code still can receive
your calling.
To unlock the locks, hold down FUNC for more than 1 second,
and Press DIAL.
TIME-OUT-TIMER (TOT)
The purpose of the time-out timer is to automatically interrupt
continuous transmitting After a specified time elapses. Holding
down [PTT] for longer than the Programmed time causes the
transceiver to stop transmitting and Generate a warning tone.
Releasing [PTT] cancels the warning tone.
Your dealer also can program a warning function that alerts
you just Before the time-out timer stops your transmission.
After [PTT] is held Down for the time specified by your dealer,
a warning tone sound that Is different from the time-out timer
tone.
Busy Channel Lockout
Activated or deactivated by your dealer, this function prevents
you from interfering with other stations that may be using the
same channel. Pressing [PTT] while the selected channel is in
use causes your transceiver to generate an audible warning
tone. Your transceiver is inhibited in this situation so it will not
transmit. Release [PTT] to cancel the alarm and restore the
receive mode.
Releasing [PTT] causes the squelch to open and the LED to
flash Orange. When the transceiver receive a signal, the LED
lights green, After the transceiver receives no further signals,
the LED flashes orange again. After a period of time
programmed by your Dealer passes during which no signal is
received, the squelch closes And LED goes OFF, Press the
[MONI] also causes the squelch to close and the LED to go
OFF.
Keypad Lockout
This function can prevent you from any error operation to your
transceiver.
Your dealer may set Keypad Lockout Alternatively: CHANNEL
SELECTOR Or 12/16 key.
CHANNEL SELECTOR can lock any key other than MONI,
FUNC, DIAL, PTT, Power/Volume.
12/16 key can only lock DIAL.
To lockout the above keys, hold down FUNC for more than 1
second and Press DIAL key.
L appears on display.
LAMP button
You can set [LAMP] IN AUTO, ENABLE or DISABLE mode.
In auto mode, the display is illuminated for 5 seconds after
Being pressed any key other than [PTT] , in ENABLE mode,
the lamp Will light after the power switched on, in DISABLE
mode, LAMP Switches off.
AUXILIARY FUNCTIONS
2
21
2