Your hearing instrument is protected by a layer of protective, hydrophobic nanocoat material.
Please follow the following instructions to prolong the durability of your hearing instruments:

1.  Keep your hearing instrument clean and dry. Wipe the case with a soft cloth or tissue after use to remove 

grease or moisture. Do not use water or solvents, as these can damage the hearing instrument(s).

2.  Never immerse hearing instruments in water or other liquids, as liquids may cause permanent damage 

to the hearing instruments.

3.  Avoid rough handling of hearing instruments or dropping them on hard surfaces or floors.
4.  Do not leave hearing instruments in or near direct heat or sunlight, such as in a hot, parked car, as 

excessive heat can cause damage or deform the casing. 

5.  Do not wear your instrument while showering, swimming, in heavy rain or in a moist atmosphere such 

as a steam bath or sauna.

6.  If your instrument does get wet, or if it has been exposed to high humidity or perspiration, it should be 

left to dry out overnight with the battery out and the battery compartment open. It is also a good idea to 
put the instrument and battery in a sealed container together with a drying agent (desiccator) overnight. 
Do not use the instrument until it is completely dry. Consult your hearing healthcare professional as to 
which drying agent to use.

7.  Remove your hearing instrument when applying such things as cosmetics, perfume, aftershave, hair 

spray, and suntan lotion. These might get into the instrument and cause damage.

i

 Daily maintenance

It is important to keep your hearing instrument clean and dry. On a daily 
basis, clean the hearing instruments using a soft cloth or tissue.

The receiver tube

The receiver tube contains the wiring to the receiver which delivers the sound to the ear canal. It is impor-
tant that the receiver tube and the receiver dome/RIE mold fits correctly in your ear. If the receiver tube 
or the receiver dome/RIE mold irritates your ear in any way and prevents you from wearing your hear ing 
instrument, please contact your hearing healthcare pro  fessional. You should never attempt to modify the 
shape of the receiver tube yourself. The receiver tube and the receiver dome/RIE mold should be cleaned 
regularly. Please see instructions in the next section.

Summary of Contents for KS661-DRW

Page 1: ...USER GUIDE RECEIVER IN EAR HEARING INSTRUMENT MODEL KS661 DRW...

Page 2: ...an outlet on a circuit different from the one in which the receiver is con nected Consult the dealer or an experienced radio TV technician for help Changes or modifications can void the user s authori...

Page 3: ...echnology and design combined with the customized device programming selected by your hearing healthcare professional will make hearing a more enjoyable experience Hearing instruments will enable you...

Page 4: ...y maintenance 23 The receiver tube 23 Cleaning the receiver tubes and domes 24 Cleaning RIE molds 24 Changing wax guard for receiver tube 25 How to apply domes 26 Using Kirkland Signature hearing inst...

Page 5: ...P receiver tube 12 HP receiver tube 13 UP receiver tube 14 Left right indicator 15 Model name and serial number 8 9 Model KS661 DRW Type VE312 Receiver in the ear RIE hearing instruments of type VE312...

Page 6: ...as usual but you will not be able to use your TV Streamer Phone Clip and Clip On Microphone At some point the battery level will not sup port the Remote Control either and you will once again hear the...

Page 7: ...ies removing the hearing instrument Sports lock The sports lock will be applied or adjusted by your hearing healthcare professional Inserting Removing hearing instruments Insertion custom RIE molds 1...

Page 8: ...2 if it was in program 2 it will switch to program 3 etc When you close the battery door and switch the instrument on it will start in program 1 Press the program or multi function button if you want...

Page 9: ...re open ing and closing the battery compartment again for any reason If the battery compartment is opened and closed during this 15 second window flight mode will resume Telephone use If your hearing...

Page 10: ...particular cellular phone or of your wireless telephony service provider If you find it difficult to obtain a good result while using your cellular phone your hearing healthcare profes sional will be...

Page 11: ...during dialing or phoning may mean that the magnet is not in the optimal position relative to the telephone receiver To avoid the issue please move the magnet to another place on the telephone receiv...

Page 12: ...with the battery out and the battery compartment open It is also a good idea to put the instrument and battery in a sealed container together with a drying agent desiccator overnight Do not use the i...

Page 13: ...a clockwise direction to ensure it is attached to the wand 4 Pull the wand and wax guard away from the tube mold 5 Insert the old wax guard into the center of the HF3 wheel 6 Dispose of the old wax g...

Page 14: ...less hearing instruments via smart phones for which the apps have been developed Use with smart phone apps Notifications of app updates should not be disabled and it is recommended that the user insta...

Page 15: ...unds from hearing instruments 3 Do not wear hearing instruments in mines oil fields or other explosive areas unless those areas are certified for hearing instrument use 4 Do not allow others to use yo...

Page 16: ...program Many hearing aid dispensers now offer programs that permit you to wear a hearing aid for a period of time for a nominal fee after which you may decide if you want to purchase the hearing aid i...

Page 17: ...f hearing aids to those individuals who have obtained a medical evaluation from a licensed physician Federal law permits a fully informed adult to sign a waiver statement declining the medical evaluat...

Page 18: ...mold Blocked wax filter Replace wax filter or consult your hearing healthcare professional Not loud enough Incorrect RIE mold placement Reinsert RIE mold Blocked RIE mold or dome Clean RIE mold repla...

Page 19: ...Consult your hearing healthcare professional Sound distorted not clear Weak battery Replace battery Improper RIE mold or dome fit Consult your hearing healthcare professional Hearing instrument damag...

Page 20: ...2 mA 70 60 50 40 30 20 10 2cc Coupler Full on gain 50dB SPL input Reference test gain 60dB SPL input 80 70 60 50 40 30 20 140 130 120 110 100 90 80 Mini RIE HP receiver Models KS661 DRW Data in accor...

Page 21: ...ncy range DIN 45605 ANSI 100 6930 Hz Current Drain 1 2 mA Mini RIE UP receiver Models KS661 DRW Note Max output using IEC 711 Ear Simulator is 136 dBSPL exceeding the 132 dBSPL threshold Data in accor...

Page 22: ...dustry standards During transport or storage the temperature should not exceed the limit values of 20C to 60C and relative humidity of 90 RH non condensing for limited time The air pressure between 50...

Page 23: ...13V1193c 400146262 US 15 02 Rev D Distributed by Costco Wholesale Corporation P O Box 34535 Seattle WA 98124 1535 USA 1 800 774 2678 Find out more at www costco com...