IMPORTANT NOTICE:
DO NOT return to place of purchase !!!
Please contact Customer Service hotline at 800-913-8999 for help
LIGHTING/SHUTDOWN
BEFORE TURNING THE GAS SUPPLY ‘ON’:
Visually inspect the hose assembly for evidence of excessive abrasion cuts or wear. If the hose leaks it must
be replaced prior to use. The hose replacement shall be that specified by the manufacturer. See parts list or
details, then call Customer Service hotline.
Is the surrounding area free of combustible materials, gasoline and other flammable vapors or liquids?
BEFORE LIGHTING:
For your safety, if re-lighting a hot heater.
Always wait at least five (5) minutes.
TO LIGHT:
(A)
Open tank enclosure door.
(B)
Make certain hose is connected to the heater intake hose and regulator is connected to the propane tank.
Check both connections to ensure they are tight and leak proof.
(C)
Turn supply tank valve in a counter clockwise direction. Check for leaks by applying soapy water to the
tank and hose connections.
(D)
Push and turn the gas control knob to ‘PILOT’ position. The igniter will spark at the same time. Firmly
press-down the knob for 15 seconds until the pilot remain lit. It might need 2 or 3 trials to light the pilot
burner. If the pilot fails to remain lit or becomes extinguished. Repeat steps B-D.
(E)
Once the pilot is lit continue to hold in the control knob for 15seconds or the until pilot remains lit after
knob is released.
(F)
The burner may now be turned to the full on position and then reduced to the desired heat range.
Caution: Avoid inhaling fumes emitted from the heater’s first use. Smoke and odor from the burning
of oils used in manufacturing will appear. Both smoke and odor will dissipate after approximately
30 minutes. The heater should NOT produce thick black smoke.
NOTE:
The burner may be noisy when initially turned on. To eliminate excessive noise from the burner,
turn the Control Knob to the pilot position. Then turn the knob to the level of heat desired.
Page 10