Page14
BURNER REMOVAL
START DISASSEMBLY FOR CLEANING BY:
Pilot
Thermocouple
Igniter
STEP 1
1.
Remove the valve panel to gain access to the pilot.
2.
Remove screw that fastens the pilot assembly to
the lower screen cone.
3.
Hold the pilot assembly with slip joint pliers, then
loosen and remove the nut at the base of the pilot.
4.
Inspect the pilot and tubing for blockage. You
should be able to see through the pilot. If it is
obstructed by debris clear with a piece of wire.
5.
The cap-like pilot orifice can be cleared with a
pin. Use the pin gently on the inside of the orifice
to clear debris. Never enlarge the opening of the
pilot orifice.