background image

 

 

 

Page 

27 

 

 

 

8.  WARRANTY 

One Year Limited Warranty 

The  limited  warranty  program  is  the  only  one  that  applies  to  this  unit,  and  it  sets  forth  all  the 
responsibilities of  KISAE.  There  is  no other  warranty,  other  than  that  described  herein.  Any  implied 
warranty of merchantability of fitness for a particular purpose on this unit is limited in duration to the 
duration of this warranty.  
This  unit  is  warranted,  to  the  original  purchaser  only,  to  be  free  of  defects  in  materials  and 
workmanship  for  one  year  from  the  date  of purchase  without additional  charge. The  warranty does 
not extend to subsequent purchasers or users. 
Manufacturer will not be responsible for any amount of damage in excess of the retail purchase price 
of the unit under any circumstances. Incidental and consequential damages are specifically excluded 
from coverage under this warranty.  
This unit is not intended for commercial use. This warranty does not apply to damage to units from 
misuse or incorrect installation/connection. Misuse includes wiring or connecting to improper polarity 
power sources.  

RETURN/REPAIR POLICY 

If you are experiencing any problems with your unit, please contact our customer service department 
at info@kisaetechnology.com or Phone 1-877-897-5778 before returning product to retail store. After 
speaking  to  a  customer  service  representative,  if  products  are  deemed  non-working  or 
malfunctioning,  the  product  may  be  returned  to  the  purchasing  store  within  30  days  of  original 
purchase. Any defective unit that is returned to manufacturer within 30 days of the date of purchase 
will be replaced free of charge.  
If  such  a  unit  is  returned  more  than  30  days  but  less  than  one  year  from  the  purchase  date, 
manufacturer will repair the unit or, at its option, replace it, free of charge. If the unit is repaired, new 
or reconditioned replacement parts may be used, at manufacturer’s option. A unit may be replaced 
with a new or reconditioned unit of the same or comparable design. The repaired or replaced unit will 
then  be  warranted  under  these  terms  for  the  remainder  of  the  warranty  period.  The  customer  is 
responsible for the shipping charges on all returned items.  

LIMITATIONS 

This  warranty  does  not  cover  accessories,  such  as  adapters  and  batteries,  damage  or  defects 
resulting  from  normal  wear  and  tear  (including  chips,  scratches,  abrasions,  discoloration  or  fading 
due  to  usage  or  exposure  to  sunlight),  accidents,  damage  during  shipping  to  our  service  facility, 
alterations, unauthorized use or repair, neglect, misuse, abuse, failure to follow instructions for care 
and maintenance, fire and flood. 

If  your  problem  is  not  covered  by  his  warranty,  call  our  Customer  Service  Department  at 
info@kisaetechnology.com or 1-877-897-5778 for general information if applicable. 

 

 

Service Contact Information 

Email:info@kisaetechnology.com 

Phone: 1-877-897-5778 

www.kisaepower.com

 

 

 

 
 

 

Printed in China 

Summary of Contents for 120V 12V-2000W-80A

Page 1: ...V 2000W 80A BIC1220080 12V 3000W 100A BIC1230100 24V 2000W 40A BIC2420040 24V 3000W 50A BIC2430050 230V Series 12V 2000W 80A BIC1220080i 12V 3000W 100A BIC1230100i 24V 2000W 40A BIC2420040i 24V 3000W...

Page 2: ...1363 BIC1220080i AU Inverter Charger 12V 2000W 80A 230VAC Australia Socket NS NZS3112 BIC1230100i EU Inverter Charger 12V 3000W 100A 230VAC Schuko Socket CEE 7 4 BIC1230100i UK Inverter Charger 12V 30...

Page 3: ...mable fumes or gases such as propane tanks or large engines AVOID covering the ventilation openings Always operate unit in an open area Prolonged exposure to high heat or freezing temperatures will de...

Page 4: ...Page 4 Table of Contents 1 INTRODUCTION 5 2 PRODUCT DESCRIPTION 5 3 UNDERSTANDING THE UNIT 6 4 INSTALLING THE UNIT 10 5 UNIT OPERATION 13 6 TROUBLESHOOTING 24 7 SPECIFICATIONS 25 8 WARRANTY 27...

Page 5: ...utility power is interrupted This manual will explain how to use this unit safely and effectively Please read and follow these instructions and precautions carefully 2 PRODUCT DESCRIPTION The Sinewave...

Page 6: ...follow these instructions can damage the unit and could also result in personal injury or loss of life CAUTION Before beginning unit installation please consider the following The unit should be used...

Page 7: ...y Actual run times may vary on battery type used b DC Fuse or Circuit Breaker DC rated fuse or DC rated circuit breaker connected along the DC positive line is required Fuse Circuit Breaker Rating 12V...

Page 8: ...ent sizes refer to the applicable installation code for the DC grounding detail In marine applications the main AC DC ground bonding may require galvanic isolators to avoid galvanic corrosion Check yo...

Page 9: ...t is used to connect to the Multi Function Display of the unit k Multi Function Display The display is used to provide unit information and for setting and programming the unit l BTS Port The port is...

Page 10: ...Input terminals will damage the unit and it cannot be repaired Damage caused by reverse polarity connection is not covered by the warranty IMPORTANT Field wiring DC terminals tightening torque 12 13 N...

Page 11: ...secure the AC Input wire For AC Output Hardwire Connections Insert the AC Input cable through the AC Output Strain relief h on the unit Connect the AC Sub Panel AC Ground wire to the AC Output Ground...

Page 12: ...rovides AC Input power to the unit If AC input source is available the Status LED amber will flash for about 10 seconds indicating the AC Input source is available It will then turn to solid green or...

Page 13: ...nput is available this Power button cannot be used to turn OFF the unit Menu SET e button can be used to view the unit setting ESCAPE h button Press and hold for 5 seconds to turn OFF or ON the AC Out...

Page 14: ...Battery Default Bulk Charge Float Voltage is 14 2V 13 8V Default Flooded Battery Default Bulk Charge Float Voltage is 14 4V 13 5V AGM Battery Default Bulk Charge Float Voltage is 14 3V 13 4V Lithium...

Page 15: ...the last bar flashing indicates the unit is running in By Pass mode and the battery is in charging process The charging stages are indicated by the number of bars 4 bars in solid indicates the battery...

Page 16: ...arting Check if any object has blocked the air flow of the unit E05 When unit is in Battery Inverter mode Input battery voltage is low and warning occurs Recharge battery as unit will shutdown shortly...

Page 17: ...y Note During blackout Power button can be used to temporarily turn inverter Off to save battery power if AC Output power is not required INT ABU Automatic Backup with Charger set to Off CHG OFF By Pa...

Page 18: ...battery capacity Inverter is disabled Power indicator On AC Output indicator Off AC Output is not available due to the inverter being set to Manual Backup Mode MBU Status indicator Off After 10 secon...

Page 19: ...acity Inverter is disabled Power indicator On AC Output indicator Off AC Output is not available due to the inverter being set to Manual Backup Mode MBU Status indicator Off After 10 seconds Display a...

Page 20: ...ON Inverter Only Unit is running as inverter only no By Pass function CHG OFF ON This setting is specially designed so that the AC load connected to AC Output is always getting clean sinewave power f...

Page 21: ...Switch On Off Status indicator solid green Note Power button function is disabled in this stage Blackout When a blackout occurs unit will not provide AC Backup Display remains On for 10 seconds with...

Page 22: ...e total AC current draw from the shore power during the By Pass Charger mode to avoid tripping the shore power Branch Breaker Absorption to Float Stage Current Setting 12V 3000W 20A 15A 10A Default 5A...

Page 23: ...d Battery Disconnect Functions Battery Under and Over Voltage Setting Battery Low Disconnect voltage has selectable range 10 5 12 0V 0 1V steps Default 10 5V The Battery Low Disconnect Voltage has to...

Page 24: ...utput switch is turned Off Press and hold the ESCAPE button for 5 seconds to turn On the AC Output AC Input Source is available but is out of the acceptance range by the unit Check AC Input Source Uni...

Page 25: ...rt RJ12 Inverter Mode Battery Voltage DC Current AC Output Power Charger Mode Charging Voltage Charging Current AC Input Power Running as Battery Charger Charging Voltage Range 13 8 14 8 VDC Float Vol...

Page 26: ...Mode Battery Voltage DC Current AC Output Power Charger Mode Charging Voltage Charging Current AC Input Power Running as Battery Charger Charging Voltage Range 27 6 29 6 VDC Float Voltage Range 26 0 2...

Page 27: ...e if products are deemed non working or malfunctioning the product may be returned to the purchasing store within 30 days of original purchase Any defective unit that is returned to manufacturer withi...

Reviews: