14
5-2. Oiling
Lubrication oil has been already filled in NC rotary table before shipping. Check that the lubrication oil is
filled to the center position of the oil gauge before operating the machine.
Replace lubrication oil every 6-month. At this time, completely drain the
oil. When filling the oil tank with lubrication/hydraulic oil, remove the chip
and foreign matter on the oil filler neck. If the chip and foreign matter are
entered, the important parts such as the worm gear, bearings, etc., are
seized and accuracy is reduced. In the air/hydraulic specification, a
clamp alarm occurs.
Fill the tank with lubricating oil to center position of oil gauge.
The shortage of oil leads to the insufficient performance of table.
Use the lubricating oil recommended in the table on the item 5-5.
Use the hydraulic oil recommended in the table on the item 5-6.
5-3. Required lubrication oil volume
(
Unit
:
liter
)
Type
TT200
Tilting axis
0.45
Gear box
0.15
Rotating axis
0.55
Filled with Daphne Multiway 32MT (IDEMITSU) before shipping.
5-4. Required operation oil volume
(For air hydro booster at pneumatic/hydraulic spec.)
(
Unit
:
liter
)
Model
TT200
Operation oil
0.35
Filled with Daphne Neo fluid 32 (IDEMITSU) before shipping.
5-5. Recommended lubrication oil
(Viscosity grade ISO VG32)
Maker
Name
IDEMITSU
Daphne Multiway 32MT
MOBIL
Vactra oil No. 1
JX NIPPON OIL & ENERGY
Uniway EV32
SHELL
Shell Tonna oil S32
COSMO
Dynaway 32
CAUTION
CAUTION
Range of refueling
Details of oil gauge