INSTALLATION GENERAL SAFETY MEASURES AND PRODUCT LIMITATIONS 

Temperature  

Probe Mounting

Run the probe into the monitored compartment and locate the sensor in a spot which will typify the average 

ambient temperature. 

Recommended location is in the center of the ceiling

. Fasten the sensor with the provided 

clamp. Make sure sensor and sensor wire are positioned and/or protected so as not to be damaged by products 

or items in the monitored area. (Seal any openings made for passage of the probe wire into the Cooler/Freezer 

on the inside and the outside of the Cooler/Freezer to prevent a pathway for condensation.

Magnetic Contacts 

Mounting

Mounting method will vary depending on the type of contacts utilized. Make sure that the operating gap  

between the magnet part and the switch part of the contacts accurately detects a door open or a door closed 

condition. (The DOOR light is on constantly when the door is open. This light may be utilized to assist in proper 

switch and magnet placement.) NOTE: For compartments with more than one door, multiple sets of contacts, 

wired in series, may be utilized to monitor multiple door’s status.

Mounting the  

75LCT onto the  

enclosure

Mount the 75LCT onto the enclosure with the provided mounting screws. If the 75LCT is mounted onto an  

outdoor type single gang outlet box, route all wiring away from the battery when the 75LCT is inserted. Inspect 

the installation for compliance with electrical code, safety, sealing against moisture and condensation, and test 

to confirm that the Product and installation are operating properly in accordance with these instructions. Periodic 

testing is recommended to ensure continued proper operation.

Resetting the 

75LCT to factory 

defaults

Press and hold reset button for 2 seconds to restore Factory Set Values.

This document contains confidential information. Dissemination, publication, copying, or duplication of this document or software described herein without prior written authorization is strictly prohibited.

kitchenbrains.com

Page 13 of 16

© 2020 Kitchen  Brains

75LCT MULTI-MONITOR  |  

OPERATING MANUAL

Summary of Contents for Modularm 75LCT

Page 1: ...0 75LCT MULTI MONITOR OPERATING MANUAL SAVE THESE INSTRUCTION FOR FUTURE REFERENCE kitchenbrains com 24 7 Toll Free Technical Support 1 800 243 9271 From the U S Canada and the Caribbean...

Page 2: ...utton Panic Entrapment Alarm is an optional accessory that provides light control panic and auto panic inside the compartment Works with the DAC 55 DL 35 75LC and Datalarm Entrapment Alarms Panic Alar...

Page 3: ...ctions with easy programming and operation OVERVIEW 75LCT FUNCTIONS The 75LCT offers the following functions Patented Operation 2 Autodetect accessories 3 AC Failure Alarm with built in rechargeable b...

Page 4: ...IP 1isavailable to be installed inside the Cooler Freezer and provides the ability to control the light within the Cooler Freezer as well as a mechanism to sound a panic alarm press the IP 1 to turn o...

Page 5: ...rohibited kitchenbrains com Page 5 of 16 2020Kitchen Brains PANIC ALARM Non Applicable DOOR AJAR Door Icon On Door Ajar Message Light Icon On Audible Alarm TABLE 1 Status of the 75LCT for Abnormal Ala...

Page 6: ...he Cooler Freezer Auto Panic can be cleared by either pressing the Control Icon Silence Icon displayed on the 75LCT screen or by opening and closing the door for those installations that have the MC 1...

Page 7: ...urn the Lights On or Off NOTE 2 With the door closed the IP 1 shall blink and beep for 40 seconds before the lights off timer expires Pressing the IP 1 at any time shall always activate the 20 minute...

Page 8: ...ure alarm condition Alarm Relay Mode Set mode of operation for relay Auto Panic Set auto panic mode PROGRAM Allows user to configure change default parameters Table 2 lists the default settings as wel...

Page 9: ...hold until the screen reads Powering Off 2 All functions are shut off 3 The battery automatically reconnects electrically the next time AC Power is applied RUN MODE All 75LCT monitoring functions take...

Page 10: ...OF INACTIVITY Probe Calibration The 75LCT comes pre calibrated to read proper temperature with Automatic Scale Conversion from F to C Calibration parameter provides a means for offsetting the display...

Page 11: ...tely rated wire insulation type voltage rating and wire gauge for all connections Supply connection wiring must be rated at least 90 C Use copper conductors only The enclosure used for mounting the Pr...

Page 12: ...the door There is no need to open or access the motion detector itself Mount the MD 1 MD 1 2 horizontally with the white oval lens facing down The red light inside of the MD 1 MD 1 2 will illuminate...

Page 13: ...ilized to assist in proper switch and magnet placement NOTE For compartments with more than one door multiple sets of contacts wired in series may be utilized to monitor multiple door s status Mountin...

Page 14: ...ion copying or duplication of this document or software described herein without prior written authorization is strictly prohibited kitchenbrains com Page 14 of 16 2020Kitchen Brains 75LCT STANDARD AC...

Page 15: ...ion publication copying or duplication of this document or software described herein without prior written authorization is strictly prohibited kitchenbrains com Page 15of 16 2020Kitchen Brains 75LCT...

Page 16: ...your Evap Monitor your Condenser Monitor your Door Openings Monitor your Temperature Monitor your Walk In s Monitor your Reach In s Kitchen Brains 905 Honeyspot Road Stratford CT 06615 kitchenbrains c...

Reviews: