3. Use a 6 mm socket and wrench or 6 mm nut driver to
remove the brass orifice from the end of gas valve. The
main burner NG orifice is located behind the LP orifice,
so no additional orifice needs to be installed.
1.A combination of pipe fittings must be used to connect the
grill to the existing gas line.
The 10 ft (3.0 m) PVC flexible gas supply hose design
certified by CSA must be used.
Pipe-joint compounds suitable for use with Natural gas
must be used Do not use tape
Make Gas Connection
must be used. Do not use tape.
There must be a certified manual shut-off valve in the gas
supply line near the grill for easy access.
2. Connect the brass connector on one end of the 10 ft (3.0m)
PVC flexible gas supply hose to the Natural gas pressure
regulator.
3. Connect the quick connector on the other end of the
10 ft (3.0 m) PVC flexible gas supply hose to the rigid
Natural gas supply pipe.
B
A
A
A. Main burner orifice
4. Reinsert the burner and reattach using the 2 screws and
cotter clip previously removed. Repeat the procedure for
each main burner.
C
D
Change Grill Main Burner Valve Orifices
1. Remove the grates and flame tamers.
2. Remove the 2 screws and cotter clip that hold the burner
IMPORTANT:
Open left and right door. Check that the orifice is
properly installed inside of the burner venturi under the control
panel.
A. Left side panel
B. Manifold
C.10 ft. (3.0 m) PVC gas hose
D. Natural gas pressure regulator/hose assembly
in place. Set the screw and clip aside. Remove the burner
from the grill by lifting the burner out.
5. Position the igniters so they are 1/8" (3.2 mm) away from
each burner.
† ®TEFLON is a registered trademark of E.I. Du Pont De Nemours
and Company.
A. Screws
B. Cotter Clip
B
A
19